Broadband Phase Correction of FT-ICR Mass Spectra via Simultaneous Excitation and Detection
The DOI matches its Crossref record.
Abstract
In typical Fourier transform ion cyclotron resonance (FT-ICR) mass spectra, temporally dispersed excitation and the delay between excitation and detection result in continuous variation of signal phase with frequency in the detected time-domain ion signal. The complex frequency-domain spectrum of such a signal is a linear combination of absorption- and dispersion-mode spectral components with corresponding asymmetric peaks. For this reason, magnitude-mode spectral display is usually employed to yield a phase-independent uniform and symmetrical peak shape at the expense of spectral resolution. In this work, we implement simultaneous excitation and detection to enable Fourier deconvolution to recover absorption-mode spectra for both low- and high-field FT-ICR instruments. These spectra yield resolving power improvement factors approaching the maximum theoretical limit of 2.0, as well as reduction in frequency assignment errors relative to conventional magnitude-mode spectra. The Fourier deconvolution procedure has the additional benefit of correcting for spectral variation resulting from nonuniform power distribution over the excitation bandwidth and the potential benefit of providing useful diagnostic information for interpretation of experimental performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Michalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citationPredator data station: A fast data acquisition system for advanced FT-ICR MS experiments
Blakney, G. T., Hendrickson, C. L., & Marshall, A. G. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.009 · Cited by 261
Self-citationFourier Transform Mass Spectrometry
Scigelova, M., Hornshaw, M., Giannakopulos, A., & Makarov, A. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009431 · Cited by 224
“the same time-domain data were shown (66).”
Metadata
- Authors
- Beu, S. C., Blakney, G. T., Quinn, J. P., Hendrickson, C. L., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-24
- Volume
- 76
- Issue
- 19
- Pages
- 5756-5761
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2019720925
- Cited by
- 60
- References
- 0
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.