The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Micromechanical Detection of Proteins Using Aptamer-Based Receptor Molecules
Abstract
We report label-free protein detection using a microfabricated cantilever-based sensor that is functionalized with DNA aptamers to act as receptor molecules. The sensor utilizes two adjacent cantilevers that constitute a sensor/reference pair and allows direct detection of the differential bending between the two cantilevers. One cantilever is functionalized with aptamers selected for Taq DNA polymerase while the other is blocked with single-stranded DNA. We have found that the polymerase-aptamer binding induces a change in surface stress, which causes a differential cantilever bending that ranges from 3 to 32 nm depending on the ligand concentration. Protein recognition on the sensor surface is specific and has a concentration dependence that is similar to that in solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Senturia, S. D. (2001) · Springer eBooks · doi:10.1007/b117574 · Cited by 2,072
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
A femtojoule calorimeter using micromechanical sensors
Barnes, J. R., Stephenson, R. J., Woodburn, C. N., O’Shea, S. J., Welland, M. E., Rayment, T., Gimzewski, J. K., & Gerber, C. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144509 · Cited by 270
Aptamer-based biosensor arrays for detection and quantification of biological macromolecules
McCauley, T. G., Hamaguchi, N., & Stanton, M. (2003) · Analytical Biochemistry · doi:10.1016/s0003-2697(03)00297-5 · Cited by 266
In vitro selection of signaling aptamers
Jhaveri, S., Rajendran, M., & Ellington, A. D. (2000) · Nature Biotechnology · doi:10.1038/82414 · Cited by 240
Self-citationAutomated selection of aptamers against protein targets translated in vitro: from gene to aptamer
Cox, J. C. (2002) · Nucleic Acids Research · doi:10.1093/nar/gnf107 · Cited by 173
Microfabricated mechanical biosensor with inherently differential readout
Savran, C. A., Burg, T. P., Fritz, J., & Manalis, S. R. (2003) · Applied Physics Letters · doi:10.1063/1.1605238 · Cited by 66
Self-citation
Cited by
Analytical applications of aptamers
Tombelli, S., Minunni, M., & Mascini, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.006 · Cited by 1,017
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Self-citationMicro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Bonora, M., Patergnani, S., Rimessi, A., De Marchi, E., Suski, J. M., Bononi, A., Giorgi, C., Marchi, S., Missiroli, S., Poletti, F., et al. (2012) · Purinergic Signalling · doi:10.1007/s11302-012-9305-8 · Cited by 644
Xiao, Y., Piorek, B. D., Plaxco, K. W., & Heeger, A. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja056555h · Cited by 527
Metadata
- Authors
- Savran, C. A., Knudsen, S. M., Ellington, A. D., & Manalis, S. R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-29
- Volume
- 76
- Issue
- 11
- Pages
- 3194-3198
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2014100786
- Cited by
- 310
- References
- 7
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.