The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Pinched Flow Fractionation: Continuous Size Separation of Particles Utilizing a Laminar Flow Profile in a Pinched Microchannel
Abstract
A concept of "pinched flow fractionation" for the continuous size separation and analysis of particles in microfabricated devices has been proposed and demonstrated. In this method, particles suspended in liquid were continuously introduced into a microchannel having a pinched segment and were aligned to one sidewall in the pinched segment by another liquid flow without particles. The particles were then separated perpendicularly to the flow direction according to their sizes by the spreading flow profile inside the microchannel. Polymer microbeads were successfully separated, and the effects of the flow rate and channel shapes on the separation performance were examined. Also, separated particles were collected independently by making branches at the end of the pinched segment. Since this method utilizes only the laminar flow profile inside a microchannel, complicated outer field control could be eliminated, which is usually required for other kinds of particle separation methods such as field flow fractionation. Also, this method can be applied both for particle size analysis and for preparation of monodispersed particles, since separation can be rapidly and continuously performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Hydrodynamic mechanisms of cell and particle trapping in microfluidics
Karimi, A., Yazdi, S., & Ardekani, A. M. (2013) · Biomicrofluidics · doi:10.1063/1.4799787 · Cited by 384
Metadata
- Authors
- Yamada, M., Nakashima, M., & Seki, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-08-12
- Volume
- 76
- Issue
- 18
- Pages
- 5465-5471
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2089919997
- Cited by
- 746
- References
- 4
- FWCI
- 10.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.