The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microfluidic System for Studying the Interaction of Nanoparticles and Microparticles with Cells
Abstract
Nanoparticles and microparticles have many potential biomedical applications ranging from imaging to drug delivery. Therefore, in vitro systems that can analyze and optimize the interaction of such particles with cells may be beneficial. Here, we report a microfluidic system that can be used to study these interactions. As a model system, we evaluated the interaction of polymeric nanoparticles and microparticles and similar particles conjugated to aptamers that recognize the transmembrane prostate specific membrane antigen (PSMA), with cells seeded in microchannels. The binding of particles to cells that expressed or did not express the PSMA (LNCaP or PC3, respectively) were evaluated with respect to changes in fluid shear stress, PSMA expression on target cells, and particle size. Nanoparticle-aptamer bioconjugates selectively adhered to LNCaP but not PC3 cells at static and low shear (<1 dyn/cm2) but not higher shear (approximately 4.5 dyn/cm2) conditions. Control nanoparticles and microparticles lacking aptamers and microparticle-aptamer bioconjugates did not adhere to LNCaP cells, even under very low shear conditions (approximately 0.28 dyn/cm2). These results demonstrate that the interaction of particles with cells can be studied under controlled conditions, which may aid in the engineering of desired particle characteristics. The scalability, low cost, reproducibility, and high-throughput capability of this technology is potentially beneficial to examining and optimizing a wide array of cell-particle systems prior to in vivo experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1998) · Nature · doi:10.1038/32020 · Cited by 76
Cited by
Kamaly, N., Yameen, B., Wu, J., & Farokhzad, O. C. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00346 · Cited by 3,070
Self-citationSelf-Assembled Targeted Nanoparticles: Evolution of Technologies and Bench to Bedside Translation
Shi, J., Xiao, Z., Kamaly, N., & Farokhzad, O. C. (2011) · Accounts of Chemical Research · doi:10.1021/ar200054n · Cited by 476
Self-citationLee, J. F., Stovall, G. M., & Ellington, A. D. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.03.015 · Cited by 398
A cell-laden microfluidic hydrogel
Ling, Y., Rubin, J., Deng, Y., Huang, C., Demirci, U., Karp, J. M., & Khademhosseini, A. (2007) · Lab on a Chip · doi:10.1039/b615486g · Cited by 395
Self-citationOrgan-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Self-citation
Metadata
- Authors
- Farokhzad, O. C., Khademhosseini, A., Jon, S., Hermmann, A., Cheng, J., Chin, C., Kiselyuk, A., Teply, B., Eng, G., & Langer, R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-22
- Volume
- 77
- Issue
- 17
- Pages
- 5453-5459
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2065683487
- Cited by
- 174
- References
- 1
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic System for Studying the Interaction of Nanoparticles and Microparticles with Cells. https://app.cochat.ai/papers/10.1021/ac050312q
- The paper
- Farokhzad, O. C., Khademhosseini, A., Jon, S., Hermmann, A., Cheng, J., Chin, C., Kiselyuk, A., Teply, B., Eng, G., & Langer, R. (2005). Microfluidic System for Studying the Interaction of Nanoparticles and Microparticles with Cells. Analytical Chemistry. https://doi.org/10.1021/ac050312q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.