The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Functionalized Conducting Polymer as an Enzyme-Immobilizing Substrate: An Amperometric Glutamate Microbiosensor for in Vivo Measurements
Abstract
The functionalized conducting polymer (CP) of 5, 2':5', 2' '-terthiophene-3'-carboxylic acid on a platinum microelectrode was prepared through the electropolymerization process using cyclic voltammetry and was used as a substrate for the immobilization of enzymes. The nanoparticles of the CP were obtained at a high scan rate in the cyclic voltammetric experiment. A needle-type amperometric glutamate microbiosensor based on the covalent immobilization of glutamate oxidase (GlOx) onto the CP layer was fabricated for in vivo measurements. The surfaces of the CP/Pt and GlOx/CP/Pt were characterized by QCM, ESCA, and AFM. The biosensor efficiently detected glutamate through the oxidation of enzymatically generated H2O2 at approximately +0.45 V versus Ag/AgCl. Various experimental parameters, such as pH, temperature, and the applied potential in the detection step were optimized. The interference effects from other biological compounds were examined, and ascorbate and dopamine interferences were observed, which were completely minimized by coimmobilizing ascorbate oxidase and by coating the sensor surface with a cationic polymer, polyethyleneimine. A linear calibration plot for glutamate was obtained between 0.2 and 100 microM with a detection limit of 0.1 +/- 0.03 microM. The proposed glutamate microbiosensor was successfully used for in vivo monitoring of the extracellular glutamate released by cocaine stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moghaddam, B. (1993) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1993.tb13387.x · Cited by 567
Enzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Research works printed but not linked: 48
- Arbizzani, C.; Mastragostino, M.; Scrosati, B. InHandbook of organicconductive molecules and polymers; Nalwa, H. S., Ed.; Wiley: Chichester, England, 1997; Vol. 4, Chapter 11, pp 595−619.
- Guiseppi-Elie, A.; Wallace, G. G.; Matsue, T. InHandbook of conductingpolymers,2nd ed.; Skotheim, T., Elsenbaumer, R., Reynolds, J. R., Eds.; Marcel Dekker: New York, 1998; Chapter 34, pp 963−991.
- Umana, M.; Waller, J.Anal. Chem.1986,58, 2979−2983 · DOI · Paper page
- Foulds N. C., 1986, J. Chem. Soc., Faraday Trans. 1, 82, 1264
- Lee T. Y., 2001, Anal. Chem., 73, 5632
- Schuhmann, W.; Huber, J.; Mirlach, A.; Daub, J.Adv, Mater.1993,5, 124−126 · doi:10.1002/adma.19930050211
- Rahman, Md. A.; Park, D.S.; Shim, Y.B.Biosens. Bioelectron.2004,19, 1565−1571 · doi:10.1016/j.bios.2003.12.005
- Wallace G. G., 1999, Trends Anal. Chem., 18, 251, 10.1016/S0165-9936(98)00113-7 · doi:10.1016/s0165-9936(98)00113-7
- Hiller M., 1996, Adv. Mater., 8, 222, 10.1002/adma.19960080306 · DOI
- Cosnier S., 1999, Anal. Chem., 71, 3697, 10.1021/ac9901788 · DOI
- Turner A. P. F., 2000, Science, 90, 1317
- Willner I., 2002, Science, 298, 2408, 10.1126/science.298.5602.2407 · DOI · Paper page
- Kissinger P. T., 1973, Brain Res., 55, 213, 10.1016/0006-8993(73)90503-9 · DOI · Paper page
- Adams R. N., 1990, Prog. Neurobiol., 35, 311, 10.1016/0301-0082(90)90014-8 · DOI
- Wightmann R. M., 1991, Proc. Natl. Acad. Sci. U.S.A., 88, 10758
- Phillips P. E. M., 2004, Nat. Neurosci., 7, 199, 10.1038/nn0304-199a · DOI
- Phillips P. E. M., 2003, Nature, 422, 618, 10.1038/nature01518 · DOI · Paper page
- Rice M. E., 2004, J. Nat. Neurosci., 7, 584
- Dale N., 2000, J. Physiol., 526, 155, 10.1111/j.1469-7793.2000.00143.x · DOI · Paper page
- Curtis D. R., 1960, J. Physiol., 150, 682
- Fonnum F., 1984, J. Neurochem., 42, 11, 10.1111/j.1471-4159.1984.tb09689.x · DOI · Paper page
- Carlsson M., 1990, Trends Neurosci., 13, 276, 10.1016/0166-2236(90)90108-M · DOI · Paper page
- Grace A. A., 1991, Neuroscience, 41, 24, 10.1016/0306-4522(91)90196-U · DOI · Paper page
- Xue C.-J., 1996, J. Neurochem., 67, 363
- Karyakin A. A., 2000, Anal. Chem., 72, 1723
- Hu Y., 1994, Brain Res., 659, 125
- Cordek J., 1999, Anal. Chem., 71, 1533, 10.1021/ac980850l · DOI
- Berners, M.; Boutelle, M.; Fillenz, M.Anal. Chem.1994,66, 2017−2021 · doi:10.1021/ac00085a016
- Niwa O., 1996, Anal. Chem., 68, 1870
- Kulagina N. V., 1999, Anal. Chem., 71, 5100, 10.1021/ac990636c · DOI · Paper page
- Poitry S., 1997, Electrochim. Acta, 42, 3223, 10.1016/S0013-4686(97)00195-3 · doi:10.1016/s0013-4686(97)00195-3
- Wollenberger U., 1989, Biosensors, 4, 391, 10.1016/0265-928X(89)80004-5 · doi:10.1016/0265-928x(89)80004-5
- Olson C. R., 1996, Anal. Chem., 68, 2169
- Rahman Md. A., 2003, Anal. Chem., 75, 1129
- Ng S. C., 1998, Polymer, 39, 4968
- Li H., 2004, Appl. Surf. Sci., 225, 169
- Stamford J. A., 1984, Brain Res., 299, 295, 10.1016/0006-8993(84)90710-8 · DOI
- Schenk J., 1982, Brain Res., 253, 356, 10.1016/0006-8993(82)90709-0 · DOI · Paper page
- Walker M. C., 1995, J. Neurochem., 65, 731, 10.1046/j.1471-4159.1995.65020725.x · DOI
- O'Neill R., Neuromethods., 268
- Kusakabe H., 1983, Agric. Biol. Chem., 47, 1328
- Espey M. G., 1998, J. Neurochem., 71, 2087, 10.1046/j.1471-4159.1998.71052079.x · DOI
- Stamford J. A., 1986, J Neurosci. Methods, 17, 29, 10.1016/0165-0270(86)90031-2 · DOI
- McFarland K., 2003, J. Neurosci., 15, 3537
- Hotsenpiller G., 2003, Neuroscience, 118, 134, 10.1016/S0306-4522(02)00951-X · DOI
- Lada M. W., 1998, J. Neurochem., 70, 625
- Shiraishi M., 1997, Brain Res., 759, 227, 10.1016/S0006-8993(97)00258-8 · DOI
- Smith J. A., 1995, Brain Res., 683, 269, 10.1016/0006-8993(95)00383-2 · DOI
Cited by
Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis
Cho, I.-H., Kim, D. H., & Park, S. (2020) · Biomaterials Research · doi:10.1186/s40824-019-0181-y · Cited by 638
Aspartate Aminotransferase (AST/GOT) and Alanine Aminotransferase (ALT/GPT) Detection Techniques
Huang, X.-J., Choi, Y.-K., Im, H.-S., Yarimaga, O., Yoon, E., & Kim, H.-S. (2006) · Sensors · doi:10.3390/s6070756 · Cited by 520
Electrochemical Sensors Based on Organic Conjugated Polymers
Rahman, M. A., Kumar, P., Park, D.-S., & Shim, Y.-B. (2008) · Sensors · doi:10.3390/s8010118 · Cited by 464
Self-citationConducting polymer nanostructures and their application in biosensors
Xia, L., Wei, Z., & Wan, M. (2010) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2009.09.029 · Cited by 402
Conducting polymer-based electrochemical biosensors for neurotransmitters: A review
Moon, J.-M., Thapliyal, N., Hussain, K. K., Goyal, R. N., & Shim, Y.-B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.069 · Cited by 390
Self-citationReview of recent advances in analytical techniques for the determination of neurotransmitters
Perry, M., Li, Q., & Kennedy, R. T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.038 · Cited by 367
Extracellular glutamate: functional compartments operate in different concentration ranges
Moussawi, K., Riegel, A., Nair, S., & Kalivas, P. W. (2011) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2011.00094 · Cited by 184
In Vivo Glutamate Sensing inside the Mouse Brain with Perovskite Nickelate–Nafion Heterostructures
Sun, Y., Nguyen, T. N. H., Anderson, A., Cheng, X., Gage, T. E., Lim, J., Zhang, Z., Zhou, H., Rodolakis, F., Zhang, Z., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c02826 · Cited by 45
Metadata
- Authors
- Rahman, M. A., Kwon, N.-H., Won, M.-S., Choe, E. S., & Shim, Y.-B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-06-24
- Volume
- 77
- Issue
- 15
- Pages
- 4854-4860
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048655182
- Cited by
- 175
- References
- 2
- FWCI
- 12.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.