The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis
Open accessAbstract
Background: The electrochemical biosensor is one of the typical sensing devices based on transducing the biochemical events to electrical signals. In this type of sensor, an electrode is a key component that is employed as a solid support for immobilization of biomolecules and electron movement. Thanks to numerous nanomaterials that possess the large surface area, synergic effects are enabled by improving loading capacity and the mass transport of reactants for achieving high performance in terms of analytical sensitivity. Main body: We categorized the current electrochemical biosensors into two groups, carbon-based (carbon nanotubes and graphene) and non-carbon-based nanomaterials (metallic and silica nanoparticles, nanowire, and indium tin oxide, organic materials). The carbon allotropes can be employed as an electrode and supporting scaffolds due to their large active surface area as well as an effective electron transfer rate. We also discussed the non-carbon nanomaterials that are used as alternative supporting components of the electrode for improving the electrochemical properties of biosensors. Conclusion: Although several functional nanomaterials have provided the innovative solid substrate for high performances, developing on-site version of biosensor that meets enough sensitivity along with high reproducibility still remains a challenge. In particular, the matrix interference from real samples which seriously affects the biomolecular interaction still remains the most critical issues that need to be solved for practical aspect in the electrochemical biosensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Tian, N., Zhou, Z.-Y., Sun, S.-G., Ding, Y., & Wang, Z. L. (2007) · Science · doi:10.1126/science.1140484 · Cited by 3,073
Transparent conductors—A status review
Chopra, K. L., Major, S. S., & Pandya, D. K. (1983) · Thin Solid Films · doi:10.1016/0040-6090(83)90256-0 · Cited by 2,700
Graphene and graphene oxide: biofunctionalization and applications in biotechnology
Wang, Y., Li, Z., Wang, J., Li, J., & Lin, Y. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.008 · Cited by 1,476
Advances in the catalysis of Au nanoparticles
Haruta, M., & Daté, M. (2001) · Applied Catalysis A: General · doi:10.1016/s0926-860x(01)00847-x · Cited by 1,414
Recent advances in graphene-based biosensors
Kuila, T., Bose, S., Khanra, P., Mishra, A. K., Kim, N. H., & Lee, J. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.039 · Cited by 1,329
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Krishnan, S. K., Singh, E., Singh, P., Meyyappan, M., & Nalwa, H. S. (2019) · RSC Advances · doi:10.1039/c8ra09577a · Cited by 785
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Cited by
Electrochemical Impedance Spectroscopy (EIS): Principles, Construction, and Biosensing Applications
Magar, H. S., Hassan, R. Y. A., & Mulchandani, A. (2021) · Sensors · doi:10.3390/s21196578 · Cited by 1,335
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Metadata
- Authors
- Cho, I.-H., Kim, D. H., & Park, S.
- Venue
- Biomaterials Research
- Published
- 2020-02-04
- Volume
- 24
- Issue
- 1
- Pages
- 6-6
- ISSN
- 1226-4601 (ISSN-L)
- 2055-7124
- OpenAlex
- W3006275452
- Cited by
- 638
- References
- 76
- FWCI
- 29.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis. https://app.cochat.ai/papers/10.1186/s40824-019-0181-y
- The paper
- Cho, I.-H., Kim, D. H., & Park, S. (2020). Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis. Biomaterials Research. https://doi.org/10.1186/s40824-019-0181-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.