CoChat

Development and Evaluation of a Reference Measurement Procedure for the Determination of Estradiol-17β in Human Serum Using Isotope-Dilution Liquid Chromatography−Tandem Mass Spectrometry

Tai, Susan S.-C., Welch, Michael J. · 2005 · Analytical Chemistry
Cited by 125

The DOI matches its Crossref record.

Abstract

Estradiol is the most potent natural estrogen and is derived from the ovaries. Its concentration in blood is measured to determine ovarian function. A reference measurement procedure for estradiol in serum involving isotope-dilution coupled with liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. A deuterated estradiol (estradiol-d3) was used as an internal standard. The estradiol and its internal standard were extracted from serum matrix using solid-phase extractions and derivatized with dansyl chloride prior to reversed-phase LC/MS/MS. The accuracy of the measurement was evaluated by a comparison of results of this reference method on lyophilized human serum reference materials for estradiol [Certified Reference Materials (CRMs) 576, 577, and 578] with the certified values determined by gas chromatography/mass spectrometry (GC/MS) reference methods and by a recovery study for the added estradiol. The results of this method for estradiol agreed with the certified values within the uncertainty of the measurements for the three CRMs. The recovery of the added estradiol ranged from 100.7 to 101.8%. This method was applied to the determination of estradiol in frozen serum samples from three individual female donors. Excellent reproducibility was obtained with within-set coefficient of variations (CVs) ranging from 0.6 to 2.2% and between-set CVs ranging from 0.2 to 0.4%. Excellent linearity was also obtained, with correlation coefficients of all linear regression lines (measured intensity ratios vs mass ratios) ranging from 0.998 to 1.000. The detection limit at a signal-to-noise ratio of approximately 3 was 0.6 pg of estradiol (or 1 ng/L, as expressed as a concentration). This well-characterized LC/MS/MS method for serum estradiol, which demonstrates good accuracy and precision, low susceptibility to interferences, and comparability with GC/MS reference methods, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for estradiol can be compared and that will serve as a standard of higher order for measurement traceability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac050837i

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 125

Metadata

Authors
Tai, S. S.-C., & Welch, M. J.
Venue
Analytical Chemistry
Published
2005-08-26
Volume
77
Issue
19
Pages
6359-6363
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2625764402
Cited by
125
References
0
FWCI
10.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Evaluation of a Reference Measurement Procedure for the Determination of Estradiol-17β in Human Serum Using Isotope-Dilution Liquid Chromatography−Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac050837i
The paper
Tai, S. S.-C., & Welch, M. J. (2005). Development and Evaluation of a Reference Measurement Procedure for the Determination of Estradiol-17β in Human Serum Using Isotope-Dilution Liquid Chromatography−Tandem Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac050837i

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.