The DOI matches its Crossref record.
Charge Transfer through DNA: A Selective Electrochemical DNA Biosensor
Abstract
The charge-transfer properties of DNA duplexes are exploited to produce a fast, simple, sensitive, and selective DNA biosensor by exposing the DNA recognition interface to a sample containing target DNA and the redox-active intercalator, anthraquinonemonosulfonic acid (AQMS). Electrochemistry from electron transfer through the DNA to AQMS intercalated into DNA duplexes can be differentiated from electrochemistry due to direct access of the AQMS to the electrode surface due to the difference in the environment of the AQMS giving a shift in the potential at which the molecule is reduced. The ability to distinguish between the two electrochemical signals enables DNA hybridization to be monitored in real time. This in situ detection scheme has good selectivity, being able to differentiate between a complementary target DNA sequence and one containing either C-A or G-A single-base mismatches. The concentration detection limit of the biosensor is 0.5 nM (1 pmol) with an assay time of 1 h. The fact that the end user is only required to simultaneously add the sample containing the target DNA and AQMS gives a DNA biosensor that is highly compatible with PCR on chip technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Mechanisms for DNA Charge Transport
Genereux, J. C., & Barton, J. K. (2010) · Chemical Reviews · doi:10.1021/cr900228f · Cited by 787
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Ciampi, S., Harper, J. B., & Gooding, J. J. (2010) · Chemical Society Reviews · doi:10.1039/b923890p · Cited by 310
Self-citation
Metadata
- Authors
- Wong, E. L. S., & Gooding, J. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-02-28
- Volume
- 78
- Issue
- 7
- Pages
- 2138-2144
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2149061780
- Cited by
- 172
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Charge Transfer through DNA: A Selective Electrochemical DNA Biosensor. https://app.cochat.ai/papers/10.1021/ac0509096
- The paper
- Wong, E. L. S., & Gooding, J. J. (2006). Charge Transfer through DNA: A Selective Electrochemical DNA Biosensor. Analytical Chemistry. https://doi.org/10.1021/ac0509096
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.