The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Solid Ionic Matrixes for Direct Tissue Analysis and MALDI Imaging
Open accessAbstract
Direct analysis of tissue by MALDI-MS allows the acquisition of its biomolecular profile while maintaining the integrity of the tissue, giving cellular localization, and avoiding tedious extraction and purification steps. However, direct tissue analysis generally leads to some extent to a lowered spectral quality due to variation in thickness, freezing tissue date, and nature of the tissue. We present here new technical developments for the direct tissue analysis of peptides with ionic liquid made of matrix mixtures (alpha-cyano-4-hydroxycinnamic acid (CHCA)/2-amino-4-methyl-5-nitropyridine and alpha-cyano-4-hydroxycinnamic acid/N,N-dimethylaniline (CHCA/DANI)). The properties of these direct tissue analysis matrixes, especially CHCA/aniline when compared to CHCA, 2,5-dihydroxybenzoic acid, and sinapinic acid, are as follows: (1) better spectral quality in terms of resolution, sensitivity, intensity, noise, number of compounds detected, and contaminant tolerance, (2) better crystallization on tissues, i.e., coverage capacity, homogeneity of crystallization, homogeneity of crystal sizes, and time of crystallization, (3) better analysis duration in term of vacuum stability, (4) better resistance to laser irradiation especially for high-frequency lasers, (5) better ionic yield in negative mode, and (6) enough fragmentation yield to use the PSD mode on sections to get structural information. Applied to MALDI imaging on a MALDI LIFT-TOF with a 50-Hz laser frequency, these ionic matrixes have allowed the realization of a new type of image in both polarities and reflector mode using the same tissue section. These results give a new outlook on peptide tissue profiling by MS, characterization of compounds from tissue slices, and MALDI-MS high-quality imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Groseclose, M. R., Massion, P. P., Chaurand, P., & Caprioli, R. M. (2008) · PROTEOMICS · doi:10.1002/pmic.200800495 · Cited by 319
Metadata
- Authors
- Lemaire, R., Tabet, J. C., Ducoroy, P., Hendra, J. B., Salzet, M., & Fournier, I.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-01-04
- Volume
- 78
- Issue
- 3
- Pages
- 809-819
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2020584856
- Cited by
- 181
- References
- 1
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solid Ionic Matrixes for Direct Tissue Analysis and MALDI Imaging. https://app.cochat.ai/papers/10.1021/ac0514669
- The paper
- Lemaire, R., Tabet, J. C., Ducoroy, P., Hendra, J. B., Salzet, M., & Fournier, I. (2006). Solid Ionic Matrixes for Direct Tissue Analysis and MALDI Imaging. Analytical Chemistry. https://doi.org/10.1021/ac0514669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.