On-Line Back-Extraction Field-Amplified Sample Injection Method for Directly Analyzing Cocaine and Thebaine in the Extractants by Solvent Microextraction
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper describes a novel method that applies on-line back-extraction field-amplified sample injection (OLBE-FASI) to the extractants by solvent microextraction (SME) in capillary zone electrophoresis (CZE). To our knowledge, it provides the first report that the water-immiscible solvent samples were directly analyzed by CZE. The water-immiscible solvent sample, sealed with a water plug in the sample vial, was used for direct electroinjection. The water plug with a moderate content of organic solvent, low-conductivity, and the presence of a small amount of H+ provided the highest sensitivity for analyzing positively chargeable compounds, such as cocaine and thebaine. The linear range was at least 2 orders of magnitude, with the square of the correlation coefficient (r2) > 0.9999, and a separate calibration over the range 0.016-10 microg/mL showed the linear range to be approaching 3 orders of magnitude. Detection limits were in the range of 2-10 ng/mL. Because the need to perform solvent exchange (from organic to aqueous solution) was eliminated, the OLBE-FASI method could be conveniently coupled with SME. In the present work, SME-OLBE-FASI-CE was validated for quantitative purposes, and applications to human urine were demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Increased Vascularization in Mice Overexpressing Angiopoietin-1
Suri, C., McClain, J., Thurston, G., McDonald, D. M., Zhou, H., Oldmixon, E. H., Sato, T. N., & Yancopoulos, G. D. (1998) · Science · doi:10.1126/science.282.5388.468 · Cited by 818
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00836-0 · Cited by 468
Cited by
Developments in single-drop microextraction
Xu, L., Basheer, C., & Lee, H. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.073 · Cited by 382
On-line sample preconcentration in capillary electrophoresis
Simpson, S. L., Quirino, J. P., & Terabe, S. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.001 · Cited by 342
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Single drop microextraction—Development, applications and future trends
Jeannot, M. A., Przyjazny, A., & Kokosa, J. M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.10.089 · Cited by 276
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Metadata
- Authors
- Fang, H., Zeng, Z., Liu, L., & Pang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-12-22
- Volume
- 78
- Issue
- 4
- Pages
- 1257-1263
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2074318054
- Cited by
- 36
- References
- 3
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.