The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microfluidic Particle Sorter Employing Flow Splitting and Recombining
Abstract
This paper describes an improved microfluidic device that enables hydrodynamic particle concentration and size-dependent separation to be carried out in a continuous manner. In our previous study, a method for hydrodynamic filtration and sorting of particles was proposed using a microchannel having multiple branch points and side channels, and it was applied for continuous concentration and separation of polymer particles and cells. In the current study, the efficiency of particle sorting was dramatically improved by geometrically splitting fluid flow from a main stream and recombining. With these operations, particles with diameters larger than a specific value move toward one sidewall in the mainstream. This control of particle positions is followed by the perfect particle alignment onto the sidewall, which increases the selectivity and recovery rates without using a liquid that does not contain particles. In this study, a microchannel having one inlet and five outlets was designed and fabricated. By simply introducing particle suspension into the device, concentrations of 2.1-3.0-microm particles were increased 60-80-fold, and they were collected independently from each outlet. In addition, it was demonstrated that the measured flow rates distributed into each side channel corresponded well to the theoretical values when regarding the microchannel network as a resistive circuit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extra-Large-Pore Zeolites with Two-Dimensional Channels Formed by 14 and 12 Rings
Paillaud, J.-L., Harbuzaru, B., Patarin, J., & Bats, N. (2004) · Science · doi:10.1126/science.1098242 · Cited by 355
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007) · Analytical Chemistry · doi:10.1021/ac070444e · Cited by 649
Metadata
- Authors
- Yamada, M., & Seki, M.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-01-06
- Volume
- 78
- Issue
- 4
- Pages
- 1357-1362
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1990393667
- Cited by
- 177
- References
- 1
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microfluidic Particle Sorter Employing Flow Splitting and Recombining. https://app.cochat.ai/papers/10.1021/ac0520083
- The paper
- Yamada, M., & Seki, M. (2006). Microfluidic Particle Sorter Employing Flow Splitting and Recombining. Analytical Chemistry. https://doi.org/10.1021/ac0520083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.