Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 649

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation

Petersson, Filip, Åberg, Lena, Swärd-Nilsson, Ann-Margret, Laurell, Thomas·2007·Analytical Chemistry

Abstract

A novel method, free flow acoustophoresis (FFA), capable of continuous separation of mixed particle suspensions into multiple outlet fractions is presented. Acoustic forces are utilized to separate particles based on their size and density. The method is shown to be suitable for both biological and nonbiological suspended particles. The microfluidic separation chips were fabricated using conventional microfabrication methods. Particle separation was accomplished by combining laminar flow with the axial acoustic primary radiation force in an ultrasonic standing wave field. Dissimilar suspended particles flowing through the 350-microm-wide channel were thereby laterally translated to different regions of the laminar flow profile, which was split into multiple outlets for continuous fraction collection. Using four outlets, a mixture of 2-, 5-, 8-, and 10-microm polystyrene particles was separated with between 62 and 94% of each particle size ending up in separate fractions. Using three outlets and three particle sizes (3, 7, and 10 microm) the corresponding results ranged between 76 and 96%. It was also proven possible to separate normally acoustically inseparable particle types by manipulating the density of the suspending medium with cesium chloride. The medium manipulation, in combination with FFA, was further used to enable the fractionation of red cells, platelets, and leukocytes. The results show that free flow acoustophoresis can be used to perform complex separation tasks, thereby offering an alternative to expensive and time-consuming methods currently in use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac070444e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 649

Metadata

Authors
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T.
Venue
Analytical Chemistry
Published
2007-06-15
Volume
79
Issue
14
Pages
5117-5123
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2041040358
Cited by
649
References
1
FWCI
16.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation. https://app.cochat.ai/papers/10.1021/ac070444e
The paper
Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T. (2007). Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation. Analytical Chemistry. https://doi.org/10.1021/ac070444e

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.