CoChat

Robust Algorithm for Alignment of Liquid Chromatography−Mass Spectrometry Analyses in an Accurate Mass and Time Tag Data Analysis Pipeline

Jaitly, Navdeep, Monroe, Matthew E., Petyuk, Vladislav A., Clauss, Therese R. W., Adkins, Joshua N., Smith, Richard D. · 2006 · Analytical Chemistry
Cited by 157

The DOI matches its Crossref record.

Abstract

Liquid chromatography coupled to mass spectrometry (LC-MS) and tandem mass spectrometry (LC-MS/MS) has become a standard technique for analyzing complex peptide mixtures to determine composition and relative abundance. Several high-throughput proteomics techniques attempt to combine complementary results from multiple LC-MS and LC-MS/MS analyses to provide more comprehensive and accurate results. To effectively collate and use results from these techniques, variations in mass and elution time measurements between related analyses need to be corrected using algorithms designed to align the various types of data: LC-MS/MS versus LC-MS/MS, LC-MS versus LC-MS/MS, and LC-MS versus LC-MS. Described herein are new algorithms referred to collectively as liquid chromatography-based mass spectrometric warping and alignment of retention times of peptides (LCMSWARP), which use a dynamic elution time warping approach similar to traditional algorithms that correct for variations in LC elution times using piecewise linear functions. LCMSWARP is compared to the equivalent approach based upon linear transformation of elution times. LCMSWARP additionally corrects for temporal drift in mass measurement accuracies. We also describe the alignment of LC-MS results and demonstrate their application to the alignment of analyses from different chromatographic systems, showing the suitability of the present approach for more complex transformations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac052197p

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 157

Metadata

Authors
Jaitly, N., Monroe, M. E., Petyuk, V. A., Clauss, T. R. W., Adkins, J. N., & Smith, R. D.
Venue
Analytical Chemistry
Published
2006-10-04
Volume
78
Issue
21
Pages
7397-7409
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2073470877
Cited by
157
References
0
FWCI
9.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust Algorithm for Alignment of Liquid Chromatography−Mass Spectrometry Analyses in an Accurate Mass and Time Tag Data Analysis Pipeline. https://app.cochat.ai/papers/10.1021/ac052197p
The paper
Jaitly, N., Monroe, M. E., Petyuk, V. A., Clauss, T. R. W., Adkins, J. N., & Smith, R. D. (2006). Robust Algorithm for Alignment of Liquid Chromatography−Mass Spectrometry Analyses in an Accurate Mass and Time Tag Data Analysis Pipeline. Analytical Chemistry. https://doi.org/10.1021/ac052197p

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.