Solution-Phase Surface Modification in Intact Poly(dimethylsiloxane) Microfluidic Channels
Abstract
An improved approach composed of an oxidation reaction in acidic H2O2 solution and a sequential silanization reaction using neat silane reagents for surface modification of poly(dimethylsiloxane) (PDMS) substrates was developed. This solution-phase approach is simple and convenient for some routine analytical applications in chemistry and biology laboratories and is designed for intact PDMS-based microfluidic devices, with no device postassembly required. Using this improved approach, two different functional groups, poly(ethylene glycol) (PEG) and amine (NH2), were introduced onto PDMS surfaces for passivation of nonspecific protein absorption and attachment of biomolecules, respectively. X-ray electron spectroscopy and temporal contact angle experiments were employed to monitor functional group transformation and dynamic characteristics of the PEG-grafted PDMS substrates; fluorescent protein solutions were introduced into the PEG-grafted PDMS microchannels to test their protein repelling characteristics. These analytical data indicate that the PEG-grafted PDMS surfaces exhibit improved short-term surface dynamics and robust long-term stability. The amino-grafted PDMS microchannels are also relatively stable and can be further activated for modifications with peptide, DNA, and protein on the surfaces of microfluidic channels. The resulting biomolecule-grafted PDMS microchannels can be utilized for cell immobilization and incubation, semiquantitative DNA hybridization, and immunoassay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Cited by
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Protein immobilization techniques for microfluidic assays
Kim, D., & Herr, A. E. (2013) · Biomicrofluidics · doi:10.1063/1.4816934 · Cited by 376
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Vaterrodt, A., Thallinger, B., Daumann, K., Koch, D., Guebitz, G. M., & Ulbricht, M. (2016) · Langmuir · doi:10.1021/acs.langmuir.5b04303 · Cited by 150
Tu, Q., Tian, C., Ma, T., Pang, L., & Wang, J. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.01.046 · Cited by 69
Kenaan, A., Li, K., Barth, I., Johnson, S., Song, J., & Krauss, T. F. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112047 · Cited by 61
Metadata
- Authors
- Sui, G., Wang, J., Lee, C.-C., Lu, W., Lee, S. P., Leyton, J. V., Wu, A. M., & Tseng, H.-R.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-06
- Volume
- 78
- Issue
- 15
- Pages
- 5543-5551
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2026896696
- Cited by
- 238
- References
- 1
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.