The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recent developments in PDMS surface modification for microfluidic devices
Abstract
PDMS is enjoying continued and ever increasing popularity as the material of choice for microfluidic devices due to its low cost, ease of fabrication, oxygen permeability and optical transparency. However, PDMS's hydrophobicity and fast hydrophobic recovery after surface hydrophilization, attributed to its low glass transition temperature of less than −120°C, negatively impacts on the performance of PDMS‐based microfluidic device components. This issue has spawned a flurry of research to devise longer lasting surface modifications of PDMS, with particular emphasis on microfluidic applications. This review will present recent research on surface modifications of PDMS using techniques ranging from metal layer coatings and layer‐by‐layer depositions to dynamic surfactant treatments and the adsorption of amphipathic proteins. We will also discuss significant advances that have been made with a broad palette of gas‐phase processing methods including plasma processing, sol–gel coatings and chemical vapor deposition. Finally, we will present examples of applications and future prospects of modified PDMS surfaces in microfluidics, in areas such as molecular separations, cell culture in microchannels and biomolecular detection via immunoassays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Cited by
Skin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M. P., Salieb-Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 853
Oxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannel
Tan, S. H., Nguyen, N.-T., Chua, Y. C., & Kang, T. G. (2010) · Biomicrofluidics · doi:10.1063/1.3466882 · Cited by 440
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Metadata
- Authors
- Zhou, J., Ellis, A. V., & Voelcker, N. H.
- Venue
- ELECTROPHORESIS
- Publisher
- Wiley
- Published
- 2009-12-28
- Volume
- 31
- Issue
- 1
- Pages
- 2-16
- ISSN
- 0173-0835 (ISSN-L)
- 1522-2683
- OpenAlex
- W2152585695
- Cited by
- 857
- References
- 1
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent developments in PDMS surface modification for microfluidic devices. https://app.cochat.ai/papers/10.1002/elps.200900475
- The paper
- Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010). Recent developments in PDMS surface modification for microfluidic devices. ELECTROPHORESIS. https://doi.org/10.1002/elps.200900475
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.