Lin, Shanhua, Shaler, Thomas A., Becker, Christopher H. · 2006 · Analytical Chemistry
Cited by 87

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A method is presented to quantify intermediate-abundance proteins in human serum using a single-quadrupole linear ion trap mass spectrometer-in contrast, for example, to a triple-quadrupole mass spectrometer. Stable-isotope-labeled (tryptic) peptides are spiked into digested protein samples as internal standards, aligned with the traditional isotope dilution approach. As a proof-of-concept experiment, four proteins of intermediate abundance were selected, coagulation factor V, adiponectin, C-reactive protein (CRP), and thyroxine binding globulin. Stable-isotope-labeled peptides were synthesized with one tryptic sequence from each of these proteins. The normal human serum concentration ranges of these proteins are from 1 to 30 microg/mL (or 20 to 650 pmol/mL). These labeled peptides and their endogenous counterparts were analyzed by LC-MS/MS using multiple reaction monitoring, a multiplexed form of the selected reaction monitoring technique. For these experiments, only one chromatographic dimension (on-line reversed-phase capillary column) was used. Improved limits of detection will result with multidimensional chromatographic methods utilizing more material per sample. Standard curves of the spiked calibrants were generated with concentrations ranging from 3 to 700 pmol/mL using both neat solutions and peptides spiked into the complex matrix of digested serum protein solution where ion suppression effects and interferences are common. Endogenous protein concentrations were determined by comparing MS/MS peak areas of the endogenous peptides to the isotopically labeled internal calibrants. The derived concentrations from a normal human serum pool (neglecting loss of material during sample processing) were 9.2, 110, 120, and 246 pmol/mL for coagulation factor V, adiponectin, CRP, and thyroxine binding globulin, respectively. These concentrations generally agree with the reported normal ranges for these proteins. As a measure of analytical reproducibility of this single-quadrupole assay, the coefficients of variance based on 12 repeated measurements for each of the endogenous tryptic peptides were 17.0, 25.4, 24.2, and 14.0% for coagulation factor V, adiponectin, CRP, and thyroxine binding globulin, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac060613f

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 87

Metadata

Authors
Lin, S., Shaler, T. A., & Becker, C. H.
Venue
Analytical Chemistry
Published
2006-07-15
Volume
78
Issue
16
Pages
5762-5767
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2075813975
Cited by
87
References
1
FWCI
4.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.