The DOI matches its Crossref record.
Subsecond Detection of Physiological Adenosine Concentrations Using Fast-Scan Cyclic Voltammetry
Abstract
Adenosine modulates blood flow and neurotransmission and may be protective during pathological conditions such as ischemia and stroke. A real-time sensor of adenosine concentrations is needed to understand its physiological actions and the extent of receptor activation. Microelectrodes are advantageous for in vivo measurements because they are small and can make fast measurements. The goal of this study was to characterize detection of physiological adenosine concentration changes at carbon-fiber microelectrodes with subsecond temporal resolution. The oxidation potential of adenosine is +1.3 V, so fast-scan cyclic voltammetry (FSCV) was performed with an applied potential from -0.4 to 1.5 V and back at 400 V/s every 100 ms. Two oxidation peaks were detected for adenosine with T-650 carbon fibers. The second oxidation peak at 1.0 V occurs after the initial oxidation at 1.5 V and is due to a sequential oxidation step. Adsorption was maximized to obtain detection limits of 15 nM, lower than basal adenosine concentrations in the brain. The electrode was insensitive to the metabolite inosine and seven times more sensitive to adenosine than ATP. The enzymatic degradation of adenosine was monitored with FSCV. This microelectrode sensor will be valuable for biological monitoring of adenosine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monitoring Rapid Chemical Communication in the Brain
Robinson, D. L., Hermans, A., Seipel, A. T., & Wightman, R. M. (2008) · Chemical Reviews · doi:10.1021/cr068081q · Cited by 669
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Review of recent advances in analytical techniques for the determination of neurotransmitters
Perry, M., Li, Q., & Kennedy, R. T. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.08.038 · Cited by 367
Fundamentals of fast-scan cyclic voltammetry for dopamine detection
Venton, B. J., & Cao, Q. (2020) · The Analyst · doi:10.1039/c9an01586h · Cited by 357
Self-citationYorgason, J. T., España, R. A., & Jones, S. R. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.001 · Cited by 315
Metadata
- Authors
- Swamy, B. E. K., & Venton, B. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-15
- Volume
- 79
- Issue
- 2
- Pages
- 744-750
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1997053106
- Cited by
- 209
- References
- 0
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subsecond Detection of Physiological Adenosine Concentrations Using Fast-Scan Cyclic Voltammetry. https://app.cochat.ai/papers/10.1021/ac061820i
- The paper
- Swamy, B. E. K., & Venton, B. J. (2007). Subsecond Detection of Physiological Adenosine Concentrations Using Fast-Scan Cyclic Voltammetry. Analytical Chemistry. https://doi.org/10.1021/ac061820i
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.