The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Free Flow Acoustophoresis: Microfluidic-Based Mode of Particle and Cell Separation
Abstract
A novel method, free flow acoustophoresis (FFA), capable of continuous separation of mixed particle suspensions into multiple outlet fractions is presented. Acoustic forces are utilized to separate particles based on their size and density. The method is shown to be suitable for both biological and nonbiological suspended particles. The microfluidic separation chips were fabricated using conventional microfabrication methods. Particle separation was accomplished by combining laminar flow with the axial acoustic primary radiation force in an ultrasonic standing wave field. Dissimilar suspended particles flowing through the 350-microm-wide channel were thereby laterally translated to different regions of the laminar flow profile, which was split into multiple outlets for continuous fraction collection. Using four outlets, a mixture of 2-, 5-, 8-, and 10-microm polystyrene particles was separated with between 62 and 94% of each particle size ending up in separate fractions. Using three outlets and three particle sizes (3, 7, and 10 microm) the corresponding results ranged between 76 and 96%. It was also proven possible to separate normally acoustically inseparable particle types by manipulating the density of the suspending medium with cesium chloride. The medium manipulation, in combination with FFA, was further used to enable the fractionation of red cells, platelets, and leukocytes. The results show that free flow acoustophoresis can be used to perform complex separation tasks, thereby offering an alternative to expensive and time-consuming methods currently in use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Microfluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Extra-Large-Pore Zeolites with Two-Dimensional Channels Formed by 14 and 12 Rings
Paillaud, J.-L., Harbuzaru, B., Patarin, J., & Bats, N. (2004) · Science · doi:10.1126/science.1098242 · Cited by 355
Fractionation of cells and subcellular particles with Percoll
Pertoft, H. (2000) · Journal of Biochemical and Biophysical Methods · doi:10.1016/s0165-022x(00)00066-x · Cited by 230
Microfluidic Particle Sorter Employing Flow Splitting and Recombining
Yamada, M., & Seki, M. (2006) · Analytical Chemistry · doi:10.1021/ac0520083 · Cited by 177
Low-temperature processing of ‘baroplastics’ by pressure-induced flow
González-León, J. A., Acar, M. H., Ryu, S., Ruzette, A.-V., & Mayes, A. M. (2003) · Nature · doi:10.1038/nature02140 · Cited by 134
Micromachined interfaces: new approaches in cell immunoisolation and biomolecular separation
Desai, T. A., Hansford, D. J., & Ferrari, M. (2000) · Biomolecular Engineering · doi:10.1016/s1389-0344(00)00063-0 · Cited by 99
Bazou, D., Kuznetsova, L. A., & Coakley, W. T. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.12.007 · Cited by 95
Cited by
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Surface acoustic wave actuated cell sorting (SAWACS)
Franke, T., Braunmüller, S., Schmid, L., Wixforth, A., & Weitz, D. A. (2010) · Lab on a Chip · doi:10.1039/b915522h · Cited by 363
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
Ultrasonic Based Tissue Modelling and Engineering
Olofsson, K., Hammarström, B., & Wiklund, M. (2018) · Micromachines · doi:10.3390/mi9110594 · Cited by 39
Metadata
- Authors
- Petersson, F., Åberg, L., Swärd-Nilsson, A.-M., & Laurell, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-06-15
- Volume
- 79
- Issue
- 14
- Pages
- 5117-5123
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2041040358
- Cited by
- 649
- References
- 14
- FWCI
- 16.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.