The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Versatile Immunosensor Using CdTe Quantum Dots as Electrochemical and Fluorescent Labels
Abstract
A versatile immunosensor using CdTe quantum dots as electrochemical and fluorescent labels has been developed for sensitive protein detection. This sandwich-type sensor is fabricated on an indium tin oxide chip covered with a well-ordered gold nanoparticle monolayer. Gel imaging systems were successfully introduced to develop a novel high-efficient optical immunoassay, which could perform simultaneous detection for the samples with a series of different concentrations of a target analyte. The linear range of this assay was between 0.1 and 500 ng/mL, and the assay sensitivity could be further increased to 0.005 ng/mL with the linear range from 0.005 to 100 ng/mL by stripping voltammetric analysis. The immunosensor showed good precision, high sensitivity, acceptable stability, and reproducibility and could be used for the detection of real sample with consistent results in comparison with those obtained by the ELISA method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dabbousi, B. O., Rodriguez-Viejo, J., Mikulec, F. V., Heine, J. R., Mattoussi, H., Ober, R., Jensen, K. F., & Bawendi, M. G. (1997) · The Journal of Physical Chemistry B · doi:10.1021/jp971091y · Cited by 4,229
Cited by
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Nanoparticles in tissue engineering: applications, challenges and prospects
Hasan, A., Morshed, M., Memic, A., Hassan, S., Webster, T., & Marei, H. (2018) · International Journal of Nanomedicine · doi:10.2147/ijn.s153758 · Cited by 496
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Quantum-Dot-Based Photoelectrochemical Sensors for Chemical and Biological Detection
Yue, Z., Lisdat, F., Parak, W. J., Hickey, S. G., Tu, L., Sabir, N., Dorfs, D., & Bigall, N. C. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am3028662 · Cited by 354
Electrochemical sensors based on graphene materials
Gan, T., & Hu, S. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0639-7 · Cited by 349
Li, L., Liu, K., Yang, G., Wang, C., Zhang, J., & Zhu, J. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201001550 · Cited by 329
Self-citationBiomolecule-nanoparticle hybrids for electrochemical biosensors
GUO, S., & DONG, S. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.10.014 · Cited by 274
Electrochemical sensors based on metal and semiconductor nanoparticles
Wang, F., & Hu, S. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0136-4 · Cited by 255
Nanotechnology-based electrochemical sensors for biomonitoring chemical exposures
Barry, R. C., Lin, Y., Wang, J., Liu, G., & Timchalk, C. A. (2009) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2008.71 · Cited by 73
Metadata
- Authors
- Cui, R., Pan, H.-C., Zhu, J.-J., & Chen, H.-Y.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-10-10
- Volume
- 79
- Issue
- 22
- Pages
- 8494-8501
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2002441094
- Cited by
- 209
- References
- 1
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.