The DOI matches its Crossref record.
Simultaneous LC/MS/MS Determination of Thiols and Disulfides in Urine Samples Based on Differential Labeling with Ferrocene-Based Maleimides
Abstract
A method for the simultaneous determination of a series of thiols and disulfides in urine samples has been developed based on the sequential labeling of free and bound thiol functionalities with two ferrocene-based maleimide reagents. The sample is first exposed to N-(2-ferroceneethyl)maleimide, thus leading to the derivatization of free thiol groups in the sample. After quantitative reaction and subsequent reduction of the disulfide-bound thiols by tris(2-carboxyethyl)phosphine, the newly formed thiol functionalities are reacted with ferrocenecarboxylic acid-(2-maleimidoyl)ethylamide. The reaction products are determined by LC/MS/MS in the multiple reaction mode, and precursor ion scan as well as neutral loss scan is applied to detect unknown further thiols. The method was successfully applied to the analysis of free and disulfide-bound thiols in urine samples. Limits of detection are 30 to 110 nM, and the linear range comprises two decades of concentration, thus covering the relevant concentration range of thiols in urine samples. The thiol and disulfide concentrations were referred to the creatinine content to compensate for different sample volumes. As some calibration standards for the disulfides are not commercially available, they were synthesized in an electrochemical flow-through cell. This allowed the synthesis of hetero- and homodimeric disulfides.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mass spectrometric based approaches in urine metabolomics and biomarker discovery
Khamis, M. M., Adamko, D. J., & El‐Aneed, A. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21455 · Cited by 342
Determination of glutathione and glutathione disulfide in biological samples: An in-depth review
Monostori, P., Wittmann, G., Karg, E., & Túri, S. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.06.016 · Cited by 301
Derivatization for liquid chromatography-mass spectrometry
Qi, B.-L., Liu, P., Wang, Q.-Y., Cai, W.-J., Yuan, B.-F., & Feng, Y.-Q. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.03.013 · Cited by 254
Guo, B., Chen, B., Liu, A., Zhu, W., & Yao, S. (2012) · Current Drug Metabolism · doi:10.2174/138920012803341401 · Cited by 80
Baghdady, Y. Z., & Schug, K. A. (2016) · Journal of Separation Science · doi:10.1002/jssc.201501003 · Cited by 54
Metadata
- Authors
- Seiwert, B., & Karst, U.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-17
- Volume
- 79
- Issue
- 18
- Pages
- 7131-7138
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2093879208
- Cited by
- 161
- References
- 0
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous LC/MS/MS Determination of Thiols and Disulfides in Urine Samples Based on Differential Labeling with Ferrocene-Based Maleimides. https://app.cochat.ai/papers/10.1021/ac071016b
- The paper
- Seiwert, B., & Karst, U. (2007). Simultaneous LC/MS/MS Determination of Thiols and Disulfides in Urine Samples Based on Differential Labeling with Ferrocene-Based Maleimides. Analytical Chemistry. https://doi.org/10.1021/ac071016b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.