Fluorescence Resonance Energy Transfer between Quantum Dots and Graphene Oxide for Sensing Biomolecules
Abstract
This work designed a novel platform for effective sensing of biomolecules by fluorescence resonance energy transfer (FRET) from quantum dots (QDs) to graphene oxide (GO). The QDs were first modified with a molecular beacon (MB) as a probe to recognize the target analyte. The strong interaction between MB and GO led to the fluorescent quenching of QDs. Upon the recognition of the target, the distance between the QDs and GO increased, and the interaction between target-bound MB and GO became weaker, which significantly hindered the FRET and, thus, increased the fluorescence of QDs. The change in fluorescent intensity produced a novel method for detection of the target. The GO-quenching approach could be used for detection of DNA sequences, with advantages such as less labor for synthesis of the MB-based fluorescent probe, high quenching efficiency and sensitivity, and good specificity. By substituting the MB with aptamer, this strategy could be conveniently extended for detection of other biomolecules, which had been demonstrated by the interaction between aptamer and protein. To the best of our knowledge, this is the first application of the FRET between QDs and GO and opens new opportunities for sensitive detection of biorecognition events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Graphene-based composite materials
Stankovich, S., Dikin, D. A., Dommett, G. H. B., Kohlhaas, K. M., Zimney, E. J., Stach, E. A., Piner, R. D., Nguyen, S. T., & Ruoff, R. S. (2006) · Nature · doi:10.1038/nature04969 · Cited by 12,922
Cited by
Graphene oxide as a chemically tunable platform for optical applications
Loh, K. P., Bao, Q., Eda, G., & Chhowalla, M. (2010) · Nature Chemistry · doi:10.1038/nchem.907 · Cited by 3,340
Graphene and graphene oxide as nanomaterials for medicine and biology application
Priyadarsini, S., Mohanty, S., Mukherjee, S., Basu, S., & Mishra, M. (2018) · Journal of Nanostructure in Chemistry · doi:10.1007/s40097-018-0265-6 · Cited by 570
Adsorption and Desorption of DNA on Graphene Oxide Studied by Fluorescently Labeled Oligonucleotides
Wu, M., Kempaiah, R., Huang, P.-J. J., Maheshwari, V., & Liu, J. (2011) · Langmuir · doi:10.1021/la1037926 · Cited by 527
Graphene Oxide as an Optical Biosensing Platform
Morales‐Narváez, E., & Merkoçi, A. (2012) · Advanced Materials · doi:10.1002/adma.201200373 · Cited by 508
Qian, Z. S., Shan, X. Y., Chai, L. J., Chen, J. R., & Feng, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.12.057 · Cited by 295
Metadata
- Authors
- Dong, H., Gao, W., Yan, F., Ji, H., & Ju, H.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-06-04
- Volume
- 82
- Issue
- 13
- Pages
- 5511-5517
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2082572892
- Cited by
- 777
- References
- 2
- FWCI
- 29.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.