New Reagents for Enhanced Liquid Chromatographic Separation and Charging of Intact Protein Ions for Electrospray Ionization Mass Spectrometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Electrospray ionization produces multiply charged ions, thereby lowering the mass-to-charge ratio for peptides and small proteins to a range readily accessed by quadrupole ion trap, orbitrap, and ion cyclotron resonance (ICR) mass analyzers (m/z = 400-2000). For Fourier transform mass analyzers (orbitrap and ICR), higher charge also improves signal-to-noise ratio, mass resolution, and mass accuracy. Addition of m-nitrobenzyl alcohol (m-NBA) or sulfolane has previously been shown to increase the charge states of proteins. Moreover, polar aprotic dimethylformamide (DMF) improves chromatographic separation of proteolytic peptides for mass analysis of solution-phase protein hydrogen/deuterium exchange for improved (78-96%) sequence coverage. Here, we show that addition of each of the various modifiers (DMF, thiodiglycol, dimethylacetamide, dimethylsulfoxide, and N-methylpyrrolidone) can significantly increase the charge states of proteins up to 78 kDa. Moreover, incorporation of the same modifiers into reversed-phase liquid chromatography solvents improves sensitivity, charging, and chromatographic resolution for intact proteins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Cited by
On the Scalability and Requirements of Whole Protein Mass Spectrometry
Compton, P. D., Zamdborg, L., Thomas, P. M., & Kelleher, N. L. (2011) · Analytical Chemistry · doi:10.1021/ac2010795 · Cited by 243
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Self-citationDada, O. O., Zhao, Y., Jaya, N., & Salas-Solano, O. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b03405 · Cited by 20
Metadata
- Authors
- Valeja, S. G., Tipton, J. D., Emmett, M. R., & Marshall, A. G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-12
- Volume
- 82
- Issue
- 17
- Pages
- 7515-7519
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2048056721
- Cited by
- 76
- References
- 2
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Reagents for Enhanced Liquid Chromatographic Separation and Charging of Intact Protein Ions for Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac1016858
- The paper
- Valeja, S. G., Tipton, J. D., Emmett, M. R., & Marshall, A. G. (2010). New Reagents for Enhanced Liquid Chromatographic Separation and Charging of Intact Protein Ions for Electrospray Ionization Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac1016858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.