CoChat

On-line HPLC Analysis System for Metabolism and Inhibition Studies in Precision-Cut Liver Slices

van Midwoud, Paul M., Janssen, Joost, Merema, Marjolijn T., de Graaf, Inge A. M., Groothuis, Geny M. M., Verpoorte, Elisabeth · 2011 · Analytical Chemistry
Cited by 40

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A novel approach for on-line monitoring of drug metabolism in continuously perifused, precision-cut liver slices (PCLS) in a microfluidic system has been developed using high-performance liquid chromatography with UV detection (HPLC-UV). In this approach, PCLS are incubated in a microfluidic device made of poly(dimethylsiloxane) (PDMS) by continuous, single-pass perifusion with fresh medium. Two syringe pumps are incorporated into the system to infuse substrates or inhibitors at varying concentrations into the perfusion medium just before the chip entrance. The medium containing the metabolites produced by the PCLS is directed toward an injection loop. Once filled, the content of this injection loop is automatically injected onto an HPLC for analysis. The on-line analysis of metabolites was tested by using the substrate, 7-hydroxycoumarin (7-HC). Rapid switching between substrate and solvent control was possible, and a direct metabolic response of the liver slice to perifusion with substrate was detected. Very stable phase II metabolism over a period of 24 h was observed. The inhibitory effect of phloxine B on the formation of 7-hydroxycoumarin glucuronide (phase II product of 7-HC) was also investigated. Phloxine B was injected into the incubation medium in increasing concentrations varying from 0 to 200 μM. The results showed a concentration-dependent inhibition of 7-HC glucuronide formation and allowed the calculation of an IC50 value (concentration in which 50% of the enzyme is inhibited) of ∼85 μM using one single liver slice. On-line detection was also shown to be advantageous for the detection of unstable metabolites. This was demonstrated by determination of the metabolites of the drug diclofenac. The reactive metabolite, acyl glucuronide, was detected at relatively high concentrations which remained very constant over a period of 4 h. In contrast, only low and decreasing amounts of diclofenac acyl glucuronide could be measured in the conventional well-plate incubation system. The advantages of this novel on-line analysis system for PCLS include the capability to obtain direct information about tissue function, assess the concentration dependence of drug-drug interactions in one single slice, and detect unstable metabolites. The system also enables fast analysis without the need to store samples, thus eliminating the associated freeze-thaw problems, and allows the simultaneous analysis of multiple metabolites.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac1018638

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 40

Metadata

Authors
van Midwoud, P. M., Janssen, J., Merema, M. T., de Graaf, I. A. M., Groothuis, G. M. M., & Verpoorte, E.
Venue
Analytical Chemistry
Published
2010-12-03
Volume
83
Issue
1
Pages
84-91
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2159555337
Cited by
40
References
3
FWCI
5.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On-line HPLC Analysis System for Metabolism and Inhibition Studies in Precision-Cut Liver Slices. https://app.cochat.ai/papers/10.1021/ac1018638
The paper
van Midwoud, P. M., Janssen, J., Merema, M. T., de Graaf, I. A. M., Groothuis, G. M. M., & Verpoorte, E. (2011). On-line HPLC Analysis System for Metabolism and Inhibition Studies in Precision-Cut Liver Slices. Analytical Chemistry. https://doi.org/10.1021/ac1018638

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.