Relative Humidity Sensors Based on an Environment-Sensitive Fluorophore in Hydrogel Films
Abstract
A fluorescence-based sensing scheme exploiting an environment-sensitive fluorophore embedded in a hydrogel has been developed for measurement of relative humidity (RH). The fluorophore, dapoxyl sulfonic acid (DSA), is incorporated into two different hydrogel films, agarose and a copolymer of acrylamide and 2-(dimethylamino)ethyl methacrylate (DMAEM) cross-linked with N,N'-methylenebisacrylamide. The swelling and contracting of the hydrogels in response to relative humidity alters the polarity of the environment of DSA, stimulating a shift in the emission wavelength. From 0 to 100% RH, acrylamide-DMAEM sensors exhibited a 40 and 15 nm wavelength shift in still air and flowing gas, respectively. Agarose sensors showed a 40 nm wavelength shift from 0 to 100% RH in still air and a 30 nm shift from 0 to 70% RH in flowing gas. Response times for both sensors were 15 min in still air and less than 5 min in flowing gas. The sensing approach is straightforward and cost-effective, yields sensors with characteristics suitable for commercial measurement of RH (i.e., sensitivity, response times, reproducibility), and allows ease of adaptability to specific RH measurement requirements. The results support the potential extension of the method to a wide variety of analytes in the vapor phase and aqueous solution by incorporation of functionalized "smart" hydrogels.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The expansion and contraction of the hydrogels at different RH changed the environmental polarity of DSA, stimulating a shift of the emission wavelength and generating the response signal.
“The expansion and contraction of the hydrogels at different RH changed the environmental polarity of the DSA, stimulating the shift of the emission wavelength and thus generating the response signal.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Tellis et al. [271]
Tellis et al. developed a fluorescence-based relative humidity measurement scheme using environmentally sensitive fluorophores embedded in hydrogels.
“Tellis et al. [271] developed a fluorescence-based relative humidity measurement scheme using environmentally sensitive fluorophores embedded in hydrogels.”
From Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. (2023) · cites this paper as Tellis et al. [271]
Cites
Physicochemical Foundations and Structural Design of Hydrogels in Medicine and Biology
Peppas, N. A., Huang, Y., Torres-Lugo, M., Ward, J. H., & Zhang, J. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.9 · Cited by 1,016 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236 · see citing works
“Tellis et al. [271] developed a fluorescence-based relative humidity measurement scheme using environmentally sensitive fluorophores embedded in hydrogels.”
- Authors
- Tellis, J. C., Strulson, C. A., Myers, M. M., & Kneas, K. A.
- Affiliations
- Elizabethtown College (US)
- Corresponding author
- Kneas, Kristi A.
- ORCID
- Tellis, John C.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-12-22
- Volume
- 83
- Issue
- 3
- Pages
- 928-932
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2332933968
- Cited by
- 75
- References
- 1
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 3 · 2023: 4 · 2022: 8 · 2021: 2 · 2020: 8 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 6 · 2015: 9 · 2014: 6 · 2013: 2 · 2012: 3
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Medicine › Hydrogels: synthesis, properties, applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- relative humidity measurement, fluorescent sensors, hydrogel films, agarose, hydrogel swelling, emission wavelength shift, stimuli-responsive hydrogels, response time (sensor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review