The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Evaluation of Digital PCR for Absolute DNA Quantification
Abstract
The emerging technique of microfluidic digital PCR (dPCR) offers a unique approach to real-time quantitative PCR for measuring nucleic acids that may be particularly suited for low-level detection. In this study, we evaluated the quantitative capabilities of dPCR when measuring small amounts (<200 copies) of DNA and investigated parameters influencing technical performance. We used various DNA templates, matrixes, and assays to evaluate the precision, sensitivity and reproducibility of dPCR, and demonstrate that this technique can be highly reproducible when performed at different times and when different primer sets are targeting the same molecule. dPCR exhibited good analytical sensitivity and was reproducible outside the range recommended by the instrument manufacturer; detecting 16 estimated targets with high precision. The inclusion of carrier had no effect on this estimated quantity, but did improve measurement precision. We report disagreement when using dPCR to measure different template types and when comparing the estimated quantities by dPCR and UV spectrophotometry. Finally, we also demonstrate that preamplification can impose a significant measurement bias. These findings provide an independent assessment of low copy molecular measurement using dPCR and underline important factors for consideration in dPCR experimental design.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“dPCR is notably less variable between experiments (28,29)”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [29]
In the citing paper
“However, such a step requires careful validation because of the potential bias that can be introduced that may outweigh the necessary precision for detecting small CNVs (29).”
From Comparison of microfluidic digital PCR and conventional quantitative PCR for measuring copy number variation (2012) · cites this paper as [29]
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Self-citationVogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Gabert, J., Beillard, E., van der Velden, V. H. J., Bi, W., Grimwade, D., Pallisgaard, N., Barbany, G., Cazzaniga, G., Cayuela, J. M., Cavé, H., et al. (2003) · Leukemia · doi:10.1038/sj.leu.2403135 · Cited by 1,284
Beillard, E., Pallisgaard, N., van der Velden, V. H. J., Bi, W., Dee, R., van der Schoot, E., Delabesse, E., Macintyre, E., Gottardi, E., Saglio, G., et al. (2003) · Leukemia · doi:10.1038/sj.leu.2403136 · Cited by 881
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Digital PCR for the molecular detection of fetal chromosomal aneuploidy
Lo, Y. M. D., Lun, F. M. F., Chan, K. C. A., Tsui, N. B. Y., Chong, K. C., Lau, T. K., Leung, T. Y., Zee, B. C. Y., Cantor, C. R., & Chiu, R. W. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705765104 · Cited by 434
Evidence that genetic instability occurs at an early stage of colorectal tumorigenesis.
Shih, I., Zhou, W. J., Goodman, S. N., Lengauer, C., Kinzler, K. W., & Vogelstein, B. (2001) · PubMed · Cited by 385
Transcription factor profiling in individual hematopoietic progenitors by digital RT-PCR
Warren, L., Bryder, D., Weissman, I. L., & Quake, S. R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608512103 · Cited by 369
Diverse Tumorigenic Pathways in Ovarian Serous Carcinoma
Singer, G., Kurman, R. J., Chang, H.-W., Cho, S. K. R., & Shih, I.-M. (2002) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)62549-7 · Cited by 340
Dube, S., Qin, J., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002876 · Cited by 302
Research works printed but not linked: 1
- Shih I. M., 2001, Cancer Res., 61, 818
Cited by
Evaluation of a Droplet Digital Polymerase Chain Reaction Format for DNA Copy Number Quantification
Pinheiro, L. B., Coleman, V. A., Hindson, C. M., Herrmann, J., Hindson, B. J., Bhat, S., & Emslie, K. R. (2012) · Analytical Chemistry · doi:10.1021/ac202578x · Cited by 1,055
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Huggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859
Self-citationQuan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
“As a result, direct quantification of low target concentration is still preferable [12,48].”
BackgroundHighly Precise Measurement of HIV DNA by Droplet Digital PCR
Strain, M. C., Lada, S. M., Luong, T., Rought, S. E., Gianella, S., Terry, V. H., Spina, C. A., Woelk, C. H., & Richman, D. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055943 · Cited by 504
“Several applications of digital PCR reported recently have demonstrated that the high accuracy possible in theory can be practically realized with a variety of clinical specimens [4,7,21,22,23,24].”
BackgroundResult
Metadata
- Authors
- Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A.
- Affiliations
- LGC (GB)
- Corresponding author
- Huggett, Jim F.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-01
- Volume
- 83
- Issue
- 17
- Pages
- 6474-6484
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1973214096
- Cited by
- 338
- References
- 32
- Citations by year
- 2026: 9 · 2025: 20 · 2024: 11 · 2023: 29 · 2022: 26 · 2021: 26 · 2020: 31 · 2019: 29 · 2018: 23 · 2017: 17 · 2016: 36 · 2015: 25 · 2014: 24 · 2013: 19 · 2012: 10
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- digital PCR, microfluidic PCR, analytical sensitivity, measurement precision, reproducibility, primer sets, experimental design
- MeSH terms
- Alcohol Dehydrogenase, DNA, Spectrophotometry, Ultraviolet, Fusion Proteins, bcr-abl, Arabidopsis Proteins, Microfluidic Analytical Techniques, Real-Time Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Digital PCR for Absolute DNA Quantification. https://app.cochat.ai/papers/10.1021/ac103230c
- The paper
- Sanders, R., Huggett, J. F., Bushell, C. A., Cowen, S., Scott, D. J., & Foy, C. A. (2011). Evaluation of Digital PCR for Absolute DNA Quantification. Analytical Chemistry. https://doi.org/10.1021/ac103230c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.