The DOI matches its Crossref record.
Dual-Emission Fluorescent Silica Nanoparticle-Based Probe for Ultrasensitive Detection of Cu2+
Abstract
An effective dual-emission fluorescent silica nanoparticle-based probe has been constructed for rapid and ultrasensitive detection of Cu(2+). In this nanoprobe, a dye-doped silica core served as a reference signal, thus providing a built-in correction for environmental effects. A response dye was covalently grafted on the surface of the silica nanoparticles through a chelating reagent for Cu(2+). The fluorescence of the response dye could be selectively quenched in the presence of Cu(2+), accompanied by a visual orange-to-green color switch of the nanoprobe. The nanoprobe provided an effective platform for reliable detection of Cu(2+) with a detection limit as low as 10 nM, which is nearly 2 × 10(3) times lower than the maximum level (∼20 μM) of Cu(2+) in drinking water permitted by the U.S. Environmental Protection Agency (EPA). The high sensitivity was attributed to the strong chelation of Cu(2+) with polyethyleneimine (PEI) and a signal amplification effect. The nanoprobe constructed by this method was very stable, enabling the rapid detection of Cu(2+) in real water samples. Good linear correlations were obtained over the concentration range from 1 × 10(-7) to 8 × 10(-7) (R(2) = 0.99) with recoveries of 103.8-99.14% and 95.5-95.14% for industrial wastewater and lake water, respectively. Additionally, the long-wavelength emission of the response dye can avoid the interference of the autofluorescence of the biosystems, which facilitated their applications in monitoring Cu(2+) in cells. Furthermore, the nanoprobe showed a good reversibility; the fluorescence can be switched "off" and "on" by an addition of Cu(2+) and EDTA, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
Self-citationLiu, S., Tian, J., Wang, L., Zhang, Y., Qin, X., Luo, Y., Asiri, A. M., Al‐Youbi, A. O., & Sun, X. (2012) · Advanced Materials · doi:10.1002/adma.201200164 · Cited by 1,550
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Ju, J., & Chen, W. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.061 · Cited by 560
The Golden Age of Thermally Activated Delayed Fluorescence Materials: Design and Exploitation
Dos Santos, J. M., Hall, D., Basumatary, B., Bryden, M., Chen, D., Choudhary, P., Comerford, T., Crovini, E., Danos, A., De, J., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00755 · Cited by 457
Self-citation
Metadata
- Authors
- Zong, C., Ai, K., Zhang, G., Li, H., & Lu, L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-03-22
- Volume
- 83
- Issue
- 8
- Pages
- 3126-3132
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2009727206
- Cited by
- 251
- References
- 0
- FWCI
- 10.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Emission Fluorescent Silica Nanoparticle-Based Probe for Ultrasensitive Detection of Cu2+. https://app.cochat.ai/papers/10.1021/ac2001324
- The paper
- Zong, C., Ai, K., Zhang, G., Li, H., & Lu, L. (2011). Dual-Emission Fluorescent Silica Nanoparticle-Based Probe for Ultrasensitive Detection of Cu2+. Analytical Chemistry. https://doi.org/10.1021/ac2001324
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.