The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Versatile Electrochemiluminescence Assays for Cancer Cells Based on Dendrimer/CdSe–ZnS–Quantum Dot Nanoclusters
Abstract
In this work, a novel dendrimer/CdSe-ZnS-quantum dot nanocluster (NC) was fabricated and used as an electrochemiluminescence (ECL) probe for versatile assays of cancer cells for the first time. A large number of CdSe-ZnS-quantum dots (QDs) were labeled on the NCs due to the many functional amine groups within the NCs, which could significantly amplify the QD's ECL signal. Capture DNA was specially designed as a high-affinity aptamer to the target cell; a novel ECL biosensor for cancer cells was directly accomplished by using the biobarcode technique to avoid cross-reaction. Moreover, magnetic beads (MBs) for aptamers immobilization were combined with the dendrimer/QD NCs probe for signal-on ECL assay of cancer cells, which greatly simplified the separation procedures and favored for the sensitivity improvement. In particular, a novel cycle-amplifying technique using a DNA device on MBs was further employed in the ECL assay of cancer cells, which greatly improved the sensitivity. To the best of our knowledge, this is the first study that the novel dendrimer/QD NCs probe combined with a DNA device cycle-amplifying technique was employed in the ECL assays of cells. Excellent discrimination against target and control cells is demonstrated, indicating that the ECL assays have great potential to provide a sensitive, selective, cost-effective, and convenient approach for early and accurate detection of cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Cited by
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Self-citationWu, P., Hou, X., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr400710z · Cited by 337
Nanomaterials-based sensitive electrochemiluminescence biosensing
Chen, Y., Zhou, S., Li, L., & Zhu, J.-J. (2017) · Nano Today · doi:10.1016/j.nantod.2016.12.013 · Cited by 337
Functionalized Quantum Dots for Biosensing and Bioimaging and Concerns on Toxicity
Wang, Y., Hu, R., Lin, G., Roy, I., & Yong, K.-T. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am302030a · Cited by 332
Metadata
- Authors
- Jie, G., Wang, L., Yuan, J., & Zhang, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-04-19
- Volume
- 83
- Issue
- 10
- Pages
- 3873-3880
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2333692084
- Cited by
- 189
- References
- 1
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.