The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magneto-Controlled Graphene Immunosensing Platform for Simultaneous Multiplexed Electrochemical Immunoassay Using Distinguishable Signal Tags
Abstract
A novel flow-through multiplexed immunoassay protocol for simultaneous electrochemical determination of carcinoembryonic (CEA) and alpha-fetoprotein (AFP) in biological fluids was designed using biofunctionalized magnetic graphene nanosheets (MGO) as immunosensing probes and multifunctional nanogold hollow microspheres (GHS) as distinguishable signal tags. The probes were fabricated by means of co-immobilization of primary anti-CEA (Ab(1)) and anti-AFP (Ab(2)) antibodies on the Fe(3)O(4) nanoparticle-coated graphene nanosheets (MGO-Ab(1,2)). The reverse-micelle method was used for the synthesis of distinguishable signal tags by encapsulation of horseradish peroxide (HRP)-thionine and HRP-ferrocene into nanogold hollow microspheres, respectively, which were utilized as labels of the corresponding GHS-Ab(1) and GHS-Ab(2). A sandwich-type immunoassay format was employed for the online detection of CEA and AFP by coupling a flow-through detection cell with an external magnet. The assay was based on the catalytic reduction of H(2)O(2) at the various peak potentials in the presence of the corresponding mediators. Experimental results revealed that the multiplexed electrochemical immunoassay enabled the simultaneous monitoring of AFP and CEA in a single run with wide working ranges of 0.01-200 ng mL(-1) for AFP and 0.01-80 ng mL(-1) for CEA. The detection limits (LODs) for both analytes at 1.0 pg mL(-1) (at 3s(B)) were very low. No obvious nonspecific adsorption and cross-talk were observed during a series of analyses to detect target analytes. Intraassay and interassay coefficients of variation were <10%. Importantly, the methodology was evaluated for the analysis of clinical serum specimens, receiving a good correlation between the flow-through multiplexed electrochemical immunoassay and an electrochemiluminescence method as a reference.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
New Horizons for Diagnostics and Therapeutic Applications of Graphene and Graphene Oxide
Feng, L., Wu, L., & Qu, X. (2013) · Advanced Materials · doi:10.1002/adma.201203229 · Cited by 632
Nanocarbons for Biology and Medicine: Sensing, Imaging, and Drug Delivery
Panwar, N., Soehartono, A. M., Chan, K. K., Zeng, S., Xu, G., Qu, J., Coquet, P., Yong, K.-T., & Chen, X. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00099 · Cited by 555
Multiplexed Point-of-Care Testing – xPOCT
Dincer, C., Bruch, R., Kling, A., Dittrich, P. S., & Urban, G. A. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.013 · Cited by 503
Sandwich-type immunosensors and immunoassays exploiting nanostructure labels: A review
Pei, X., Zhang, B., Tang, J., Liu, B., Lai, W., & Tang, D. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.10.060 · Cited by 454
Self-citation
Metadata
- Authors
- Tang, J., Tang, D., Niessner, R., Chen, G., & Knopp, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-06-03
- Volume
- 83
- Issue
- 13
- Pages
- 5407-5414
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2016670672
- Cited by
- 231
- References
- 1
- FWCI
- 21.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.