The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Open accessAbstract
Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Shapiro, H. M. (2003) · Wiley eBooks · doi:10.1002/0471722731 · Cited by 2,671
Topological structural analysis of digitized binary images by border following
Suzuki, S., & be, K. (1985) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(85)90016-7 · Cited by 2,663
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Self-citationLeukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H. (2009) · Lab on a Chip · doi:10.1039/b910053a · Cited by 408
Practical Flow Cytometry, 4th Edition
Ng, V. L. (2004) · Shock · doi:10.1097/00024382-200401000-00017 · Cited by 346
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Cost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Self-citationFlow Cytometry: First Principles
Givan, A. L. (2001) · Wiley eBooks · doi:10.1002/0471223948 · Cited by 307
A Microchip CD4 Counting Method for HIV Monitoring in Resource-Poor Settings
Rodriguez, W. R., Christodoulides, N., Floriano, P. N., Graham, S., Mohanty, S., Dixon, M., Hsiang, M., Peter, T., Zavahir, S., Thior, I., et al. (2005) · PLoS Medicine · doi:10.1371/journal.pmed.0020182 · Cited by 196
Telemedicine and teledermatology: Past, present and future
Wurm, E. M. T., Hofmann‐Wellenhof, R., Wurm, R., & Soyer, H. P. (2007) · JDDG Journal der Deutschen Dermatologischen Gesellschaft · doi:10.1111/j.1610-0387.2007.06440.x · Cited by 95
Cheng, X., Irimia, D., Dixon, M. A., Ziperstein, J. C., Demirci, U., Zamir, L., Tompkins, R. G., Toner, M., & Rodriguez, W. R. (2007) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e3180500303 · Cited by 89
Feasibility and acceptance of telemedicine for wound care in patients with chronic leg ulcers
Hofmann‐Wellenhof, R., Salmhofer, W., Binder, B., Okcu, A., Kerl, H., & Soyer, H. P. (2006) · Journal of Telemedicine and Telecare · doi:10.1258/135763306777978407 · Cited by 82
Jokerst, J. V., Floriano, P. N., Christodoulides, N. J., Simmons, G. W., & McDevitt, J. T. (2008) · Lab on a Chip · doi:10.1039/b817116e · Cited by 75
Fluorescence spectrometer-on-a-fluidic-chip
Schmidt, O., Baßler, M., Kiesel, P., Knollenberg, C., & Johnson, N. M. (2007) · Lab on a Chip · doi:10.1039/b618879f · Cited by 56
An integrated microfluidic system for counting of CD4+/CD8+ T lymphocytes
Wang, J.-H., Wang, C., Lin, C.-C., Lei, H., & Lee, G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0687-z · Cited by 32
Comparison of Inlet Geometry in Microfluidic Cell Affinity Chromatography
Li, P., Tian, Y. P., & Pappas, D. (2011) · Analytical Chemistry · doi:10.1021/ac102975g · Cited by 30
Dual of Shack-Hartmann Optometry using Mobile Phones
Pamplona, V. F., Mohan, A., Oliveira, M. M., & Raskar, R. (2010) · Frontiers in Optics · doi:10.1364/fio.2010.ftub4 · Cited by 8
Cited by
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Self-citationBiosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
The Smartphone Psychology Manifesto
Miller, G. (2012) · Perspectives on Psychological Science · doi:10.1177/1745691612441215 · Cited by 624
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies
Jung, W., Han, J., Choi, J.-W., & Ahn, C. H. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.09.024 · Cited by 510
Metadata
- Authors
- Zhu, H., Mavandadi, S., Coskun, A. F., Yaglidere, O., & Ozcan, A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-08-02
- Volume
- 83
- Issue
- 17
- Pages
- 6641-6647
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W1988906448
- Cited by
- 390
- References
- 22
- FWCI
- 22.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.