The DOI matches its Crossref record.
Lensfree microscopy on a cellphone
Open accessAbstract
We demonstrate lensfree digital microscopy on a cellphone. This compact and light-weight holographic microscope installed on a cellphone does not utilize any lenses, lasers or other bulky optical components and it may offer a cost-effective tool for telemedicine applications to address various global health challenges. Weighing approximately 38 grams (<1.4 ounces), this lensfree imaging platform can be mechanically attached to the camera unit of a cellphone where the samples are loaded from the side, and are vertically illuminated by a simple light-emitting diode (LED). This incoherent LED light is then scattered from each micro-object to coherently interfere with the background light, creating the lensfree hologram of each object on the detector array of the cellphone. These holographic signatures captured by the cellphone permit reconstruction of microscopic images of the objects through rapid digital processing. We report the performance of this lensfree cellphone microscope by imaging various sized micro-particles, as well as red blood cells, white blood cells, platelets and a waterborne parasite (Giardia lamblia).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Self-citationCell-Phone-Based Platform for Biomedical Device Development and Education Applications
Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017150 · Cited by 339
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
Self-citation
Metadata
- Authors
- Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 14
- Pages
- 1787
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2111765476
- Cited by
- 480
- References
- 0
- FWCI
- 20.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lensfree microscopy on a cellphone. https://app.cochat.ai/papers/10.1039/c003477k
- The paper
- Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010). Lensfree microscopy on a cellphone. Lab on a Chip. https://doi.org/10.1039/c003477k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.