The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Cell-Phone-Based Platform for Biomedical Device Development and Education Applications
Open accessAbstract
In this paper we report the development of two attachments to a commercial cell phone that transform the phone's integrated lens and image sensor into a 350x microscope and visible-light spectrometer. The microscope is capable of transmission and polarized microscopy modes and is shown to have 1.5 micron resolution and a usable field-of-view of 150 x 50 with no image processing, and approximately 350 x 350 when post-processing is applied. The spectrometer has a 300 nm bandwidth with a limiting spectral resolution of close to 5 nm. We show applications of the devices to medically relevant problems. In the case of the microscope, we image both stained and unstained blood-smears showing the ability to acquire images of similar quality to commercial microscope platforms, thus allowing diagnosis of clinical pathologies. With the spectrometer we demonstrate acquisition of a white-light transmission spectrum through diffuse tissue as well as the acquisition of a fluorescence spectrum. We also envision the devices to have immediate relevance in the educational field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morphological Image Analysis: Principles and Applications
(2000) · Sensor Review · doi:10.1108/sr.2000.08720cae.001 · Cited by 3,537
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Evaluation of focus measures in multi-focus image fusion
Huang, W., & Jing, Z. (2007) · Pattern Recognition Letters · doi:10.1016/j.patrec.2006.09.005 · Cited by 566
Lensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Lensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A. (2010) · Optics Express · doi:10.1364/oe.18.011181 · Cited by 440
Selinummi, J., Seppälä, J., Yli-Harja, O., & Puhakka, J. A. (2005) · BioTechniques · doi:10.2144/000112018 · Cited by 263
Bargo, P. R., Prahl, S. A., Goodell, T. T., Sleven, R. A., Koval, G., Blair, G., & Jacques, S. L. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1921907 · Cited by 199
Optical imaging for cervical cancer detection: solutions for a continuing global problem
Thekkek, N., & Richards-Kortum, R. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2462 · Cited by 176
Lookup table–based inverse model for determining optical properties of turbid media
Rajaram, N., Nguyen, T. H., & Tunnell, J. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2981797 · Cited by 168
Detection of waterborne parasites using field-portable and cost-effective lensfree microscopy
Mudanyali, O., Oztoprak, C., Tseng, D. K., Erlinger, A., & Özcan, A. (2010) · Lab on a Chip · doi:10.1039/c004829a · Cited by 158
Cited by
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Quantitative Imaging with a Mobile Phone Microscope
Skandarajah, A., Reber, C. D., Switz, N. A., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096906 · Cited by 196
Mobile Device for Disease Diagnosis and Data Tracking in Resource-Limited Settings
Chin, C. D., Cheung, Y. K., Laksanasopin, T., Modena, M. M., Chin, S. Y., Sridhara, A. A., Steinmiller, D., Linder, V., Mushingantahe, J., Umviligihozo, G., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.199596 · Cited by 75
Metadata
- Authors
- Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-03-02
- Volume
- 6
- Issue
- 3
- Pages
- e17150
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2096200085
- Cited by
- 339
- References
- 13
- FWCI
- 17.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cell-Phone-Based Platform for Biomedical Device Development and Education Applications. https://app.cochat.ai/papers/10.1371/journal.pone.0017150
- The paper
- Smith, Z. J., Chu, K., Espenson, A. R., Rahimzadeh, M., Gryshuk, A., Molinaro, M., Dwyre, D. M., Lane, S., Matthews, D., & Wachsmann-Hogiu, S. (2011). Cell-Phone-Based Platform for Biomedical Device Development and Education Applications. PLoS ONE. https://doi.org/10.1371/journal.pone.0017150
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.