CoChat

Clinically Relevant Microfluidic Magnetophoretic Isolation of Rare-Cell Populations for Diagnostic and Therapeutic Monitoring Applications

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

Cells of biomedical interest are, despite their functional significance, often present in very small numbers. Therefore the analysis and isolation of previously inaccessible rare cells, such as peripheral hematopoietic stem cells, endothelial progenitor cells, or circulating tumor cells, require efficient, sensitive, and specific procedures that do not compromise the viability of the cells. The current study builds on previous work on a rationally designed microfluidic magnetophoretic cell separation platform capable of throughputs of 240 μL min(-1). Proof-of-concept was first conducted using MCF-7 (1-1000 total cells) as the target rare cell spiked into high concentrations of Raji B-lymphocyte nontarget cells (~10(6) total cells). These experiments lead to the establishment of a magnet-based separation for the isolation of 50 MCF-7 cells directly from whole blood. Results show an efficiency of collection greater than 85%, with a purity of over 90%. Next, resident endothelial progenitor cells and hematopoietic stem cells are directly isolated from whole human blood in a rapid and efficient fashion (>96%). Both cell populations could be simultaneously isolated and, via immunofluorescent staining, individually identified and enumerated. Overall, the presented device illustrates a viable separation platform for high purity, efficient, and rapid collection of rare cell populations directly from whole blood samples.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac2022844

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 3

  1. Murthy, S. K.; Radisic, M.InEncyclopedia of Microfluidics and Nanofluidics;Li, D., Ed.Springer:New York, 2008; p202.
  2. Carpino F., 2005, J. Phys.: Conf. Ser., 17, 174
  3. Xia Y. N., 1998, Angew. Chem., Int. Ed., 37, 551

Cited by

Items 101–107 of 107

Metadata

Authors
Plouffe, B. D., Mahalanabis, M., Lewis, L. H., Klapperich, C. M., & Murthy, S. K.
Affiliations
Boston University (US)
Corresponding author
Murthy, Shashi K.
Venue
Analytical Chemistry
Published
2012-01-27
Volume
84
Issue
3
Pages
1336-1344
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2071780957
Cited by
96
References
58
Citations by year
2025: 2 · 2023: 4 · 2022: 7 · 2021: 10 · 2020: 3 · 2019: 2 · 2018: 14 · 2017: 11 · 2016: 9 · 2015: 7 · 2014: 5 · 2013: 15 · 2012: 6
FWCI
6.01
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation
  • Division of Chemical, Bioengineering, Environmental, and Transport Systems
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Field-Flow Fractionation Techniques
Keywords
microfluidic cell separation, magnetophoresis, rare cell isolation, circulating tumor cells, MCF-7 cells, endothelial progenitor cells, hematopoietic stem cells, whole blood, therapeutic monitoring, diagnostic monitoring
MeSH terms
Cells, Cultured, Flow Cytometry, Hematopoietic Stem Cells, Humans, Neoplastic Cells, Circulating, RNA, Stem Cells, Immunomagnetic Separation, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.