Clinically Relevant Microfluidic Magnetophoretic Isolation of Rare-Cell Populations for Diagnostic and Therapeutic Monitoring Applications
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Cells of biomedical interest are, despite their functional significance, often present in very small numbers. Therefore the analysis and isolation of previously inaccessible rare cells, such as peripheral hematopoietic stem cells, endothelial progenitor cells, or circulating tumor cells, require efficient, sensitive, and specific procedures that do not compromise the viability of the cells. The current study builds on previous work on a rationally designed microfluidic magnetophoretic cell separation platform capable of throughputs of 240 μL min(-1). Proof-of-concept was first conducted using MCF-7 (1-1000 total cells) as the target rare cell spiked into high concentrations of Raji B-lymphocyte nontarget cells (~10(6) total cells). These experiments lead to the establishment of a magnet-based separation for the isolation of 50 MCF-7 cells directly from whole blood. Results show an efficiency of collection greater than 85%, with a purity of over 90%. Next, resident endothelial progenitor cells and hematopoietic stem cells are directly isolated from whole human blood in a rapid and efficient fashion (>96%). Both cell populations could be simultaneously isolated and, via immunofluorescent staining, individually identified and enumerated. Overall, the presented device illustrates a viable separation platform for high purity, efficient, and rapid collection of rare cell populations directly from whole blood samples.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, current commercial immunomagnetic products for CTCs require several sample processing and transfer steps, which may result in the loss of CTCs during the operation process.20”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [20]
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Circulating endothelial progenitor cells, vascular function, and cardiovascular risk
Hill, J. M., Zalos, G., Halcox, J. P. J., Schenke, W. H., Waclawiw, M. A., Quyyumi, A. A., & Finkel, T. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022287 · Cited by 3,423
Circulating endothelial progenitor cells and cardiovascular outcomes
Werner, N., Kosiol, S., Schiegl, T., Ahlers, P., Walenta, K., Link, A., Böhm, M., & Nickenig, G. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043814 · Cited by 2,048
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Yoder, M. C., Mead, L. E., Prater, D., Krier, T. R., Mroueh, K. N., Li, F., Krasich, R., Temm, C. J., Prchal, J. T., & Ingram, D. A. (2007) · Blood · doi:10.1182/blood-2006-08-043471 · Cited by 1,477
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
THE VISCOSITY OF THE BLOOD IN NARROW CAPILLARY TUBES
Fåhræus, R., & Lindqvist, T. (1931) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1931.96.3.562 · Cited by 1,268
Circulating tumor cells: approaches to isolation and characterization
Yu, M., Stott, S., Toner, M., Maheswaran, S., & Haber, D. A. (2011) · Journal of Cell Biology · doi:10.1083/jcb.201010021 · Cited by 1,089
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Pamme, N., & Wilhelm, C. (2006) · Lab on a Chip · doi:10.1039/b604542a · Cited by 497
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353
Microfluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays
Saliba, A.-E., Saias, L., Psychari, E., Minc, N., Simon, D., Bidard, F.-C., Mathiot, C., Pierga, J.-Y., Fraisier, V., Salamero, J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001515107 · Cited by 337
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Therapeutic Relevance of CD34 Cell Dose in Blood Cell Transplantation for Cancer Therapy
Siena, S., Schiavo, R., Pedrazzoli, P., & Carlo-Stella, C. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.6.1360 · Cited by 312
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Margination of leukocytes in blood flow through small tubes
Goldsmith, H. L., & Spain, S. (1984) · Microvascular Research · doi:10.1016/0026-2862(84)90054-2 · Cited by 239
Autologous hematopoietic stem cell transplantation for autoimmune diseases
Gratwohl, A., Passweg, J., Bocelli-Tyndall, C., Fassas, A., van Laar, J. M., Farge, D., Andolina, M., Arnold, R., Carreras, E., Finke, J., et al. (2005) · Bone Marrow Transplantation · doi:10.1038/sj.bmt.1704892 · Cited by 215
Isolation of tumor cells using size and deformation
Mohamed, H., Murray, M., Turner, J. N., & Caggana, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.036 · Cited by 208
Rare Cell Separation and Analysis by Magnetic Sorting
Zborowski, M., & Chalmers, J. J. (2011) · Analytical Chemistry · doi:10.1021/ac200550d · Cited by 195
Rare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
Autologous Hematopoietic Stem-Cell Transplantation for Multiple Myeloma
Harousseau, J.-L., & Moreau, P. (2009) · New England Journal of Medicine · doi:10.1056/nejmct0805626 · Cited by 186
Adhesion based detection, sorting and enrichment of cells in microfluidic Lab-on-Chip devices
Didar, T. F., & Tabrizian, M. (2010) · Lab on a Chip · doi:10.1039/c0lc00130a · Cited by 173
Surface-Immobilized Aptamers for Cancer Cell Isolation and Microscopic Cytology
Wan, Y., Kim, Y. T., Li, N., Cho, S. K., Bachoo, R. M., Ellington, A. D., & Iqbal, S. M. (2010) · Cancer Research · doi:10.1158/0008-5472.can-10-0568 · Cited by 162
Design of a microfabricated magnetic cell separator
Berger, M., Castelino, J., Huang, R., Shah, M., & Austin, R. H. (2001) · Electrophoresis · doi:10.1002/1522-2683(200110)22:18<3883::aid-elps3883>3.0.co;2-4 · Cited by 157
Flow Through, Immunomagnetic Cell Separation
Chalmers, J. J., Zborowski, M., Sun, L., & Moore, L. (1998) · Biotechnology Progress · doi:10.1021/bp970140l · Cited by 151
Microfluidic high gradient magnetic cell separation
Inglis, D. W., Riehn, R. E., Sturm, J. C., & Austin, R. H. (2006) · Journal of Applied Physics · doi:10.1063/1.2165782 · Cited by 143
Plouffe, B. D., Njoka, D. N., Harris, J., Liao, J., Horick, N. K., Radisic, M., & Murthy, S. K. (2007) · Langmuir · doi:10.1021/la0700220 · Cited by 139
Self-citationMicro- and nanotechnology in cell separation
Radisic, M., Iyer, R. K., & Murthy, S. K. (2006) · International Journal of Nanomedicine · doi:10.2147/nano.2006.1.1.3 · Cited by 134
Self-citationPamme, N., Eijkel, J. C. T., & Manz, A. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.04.008 · Cited by 125
High gradient magnetic separation of red cells from whole blood
Melville, D., Paul, F., & Roath, S. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058970 · Cited by 120
Immunomagnetic cell sorting—pushing the limits
Thiel, A., Scheffold, A., & Radbruch, A. (1998) · Immunotechnology · doi:10.1016/s1380-2933(98)00010-4 · Cited by 118
Gp, D. (1965) · PubMed · Cited by 106
Determinants of Leukocyte Margination in Rectangular Microchannels
Jain, A., & Munn, L. L. (2009) · PLoS ONE · doi:10.1371/journal.pone.0007104 · Cited by 105
Hatch, A., Hansmann, G., & Murthy, S. K. (2011) · Langmuir · doi:10.1021/la105016a · Cited by 94
Self-citationHuman immunodeficiency virus induction of malignant transformation in human B lymphocytes.
Laurence, J. C., & Astrin, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.17.7635 · Cited by 94
Rheological properties of the blood influencing selectin-mediated adhesion of flowing leukocytes
Abbitt, K. B., & Nash, G. B. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00408.2002 · Cited by 90
Van Craenenbroeck, E. M. F., Conraads, V. M. A., Van Bockstaele, D. R., Haine, S. E., Vermeulen, K., Van Tendeloo, V. F., Vrints, C. J., & Hoymans, V. Y. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2007.12.006 · Cited by 77
Michallet, M., Dreger, P., Sutton, L., Brand, R., Richards, S. M., van Os, M., Sobh, M., Choquet, S., Corront, B., Dearden, C. E., et al. (2010) · Blood · doi:10.1182/blood-2010-09-308775 · Cited by 67
Microfluidic-based diagnostics for cervical cancer cells
Du, Z., Colls, N. R., Cheng, K. H., Vaughn, M. W., & Gollahon, L. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.09.005 · Cited by 61
Plouffe, B. D., Brown, M. A., Iyer, R. K., Radisic, M., & Murthy, S. K. (2009) · Lab on a Chip · doi:10.1039/b823523f · Cited by 59
Self-citationComputational design optimization for microfluidic magnetophoresis
Plouffe, B. D., Lewis, L. H., & Murthy, S. K. (2011) · Biomicrofluidics · doi:10.1063/1.3553239 · Cited by 52
Self-citationDetection of circulating tumour cells with the magnetic activated cell sorter
Wong, L. S., Bateman, W. J., Morris, A. G., & Fraser, I. A. (1995) · British journal of surgery · doi:10.1002/bjs.1800821012 · Cited by 51
Suzuki, S., Shimotsu, N., Honda, S., Arai, A., & Nakanishi, H. (2001) · Electrophoresis · doi:10.1002/1522-2683(200110)22:18<4023::aid-elps4023>3.0.co;2-p · Cited by 50
Putnam, D. D., Namasivayam, V., & Burns, M. A. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10511 · Cited by 46
Sequential CD34 cellfractionation by magnetophoresis in a magnetic dipole flow sorter
Schneider, T., Karl, S., Moore, L. R., Chalmers, J. J., Williams, P. S., & Zborowski, M. (2009) · The Analyst · doi:10.1039/b908210g · Cited by 43
Green, J. V., & Murthy, S. K. (2009) · Lab on a Chip · doi:10.1039/b906768j · Cited by 39
Self-citationClinical aspects of T‐ and B‐lymphocytes in rheumatic diseases
Messner, R. P. (1974) · Arthritis & Rheumatism · doi:10.1002/art.1780170402 · Cited by 38
Richel, D. J., Johnsen, H. E., Canon, J.-L., Guillaume, T., Schaafsma, M., Schenkeveld, C., Hansen, S., McNiece, I., Gringeri, A., Briddell, R. A., et al. (2000) · Bone Marrow Transplantation · doi:10.1038/sj.bmt.1702136 · Cited by 37
Quadrupole Magnetic Sorting of Porcine Islets of Langerhans
Shenkman, R. M., Chalmers, J. J., Hering, B. J., Kirchhof, N., & Papas, K. K. (2009) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2008.0343 · Cited by 20
Wang, G., Li, Y., Yu, Y., Yu, B., Zhang, Z.-Y., Liu, Y., & Wang, S. (2009) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2008.05633.x · Cited by 14
Endothelial progenitor cells: Cellular biomarkers in vascular disease
Hristov, M., & Weber, C. (2008) · Drug Discovery Today Disease Mechanisms · doi:10.1016/j.ddmec.2008.07.001 · Cited by 10
T AND B LYMPHOCYTES IN SPLEEN IN HODGKIN'S DISEASE
Joseph, R., & Belpomme, D. (1975) · The Lancet · doi:10.1016/s0140-6736(75)91660-8 · Cited by 9
Cancelas, J. A., Querol, S., Martín-Henao, G. A., Canals, C., Azqueta, C., Pétriz, J., Inglés‐Esteve, J., Amill, B., & García, J. (1996) · Pure and Applied Chemistry · doi:10.1351/pac199668101897 · Cited by 7
Research works printed but not linked: 3
- Murthy, S. K.; Radisic, M.InEncyclopedia of Microfluidics and Nanofluidics;Li, D., Ed.Springer:New York, 2008; p202.
- Carpino F., 2005, J. Phys.: Conf. Ser., 17, 174
- Xia Y. N., 1998, Angew. Chem., Int. Ed., 37, 551
Cited by
D'Souza-Schorey, C., & Clancy, J. W. (2012) · Genes & Development · doi:10.1101/gad.192351.112 · Cited by 528
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
“By employing either permanent magnets (Adams et al 2008b) or electromagnets (Plouffe et al 2012), cells of interest can be rapidly isolated (>250 µl min−1) from large sample volumes (>10 ml).”
BackgroundMethodInfluentialSelf-citationRare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Nasiri, R., Shamloo, A., Ahadian, S., Amirifar, L., Akbari, J., Goudie, M. J., Lee, K., Ashammakhi, N., Dokmeci, M. R., Di Carlo, D., et al. (2020) · Small · doi:10.1002/smll.202000171 · Cited by 244
Metadata
- Authors
- Plouffe, B. D., Mahalanabis, M., Lewis, L. H., Klapperich, C. M., & Murthy, S. K.
- Affiliations
- Boston University (US)
- Corresponding author
- Murthy, Shashi K.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-27
- Volume
- 84
- Issue
- 3
- Pages
- 1336-1344
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2071780957
- Cited by
- 96
- References
- 58
- Citations by year
- 2025: 2 · 2023: 4 · 2022: 7 · 2021: 10 · 2020: 3 · 2019: 2 · 2018: 14 · 2017: 11 · 2016: 9 · 2015: 7 · 2014: 5 · 2013: 15 · 2012: 6
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Field-Flow Fractionation Techniques
- Keywords
- microfluidic cell separation, magnetophoresis, rare cell isolation, circulating tumor cells, MCF-7 cells, endothelial progenitor cells, hematopoietic stem cells, whole blood, therapeutic monitoring, diagnostic monitoring
- MeSH terms
- Cells, Cultured, Flow Cytometry, Hematopoietic Stem Cells, Humans, Neoplastic Cells, Circulating, RNA, Stem Cells, Immunomagnetic Separation, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.