CoChat

Sensitive and Reproducible Intact Mass Analysis of Complex Protein Mixtures with Superficially Porous Capillary Reversed-Phase Liquid Chromatography Mass Spectrometry

Roth, Michael J., Plymire, Daniel A., Chang, Audrey N., Kim, Jaekuk, Maresh, Erica M., Larson, Shane E., Patrie, Steven M. · 2011 · Analytical Chemistry
Cited by 41

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The compatibility of superficially porous (SP) resin for label-free intact protein analysis with online capillary LC/MS is demonstrated to give improved chromatographic resolution, sensitivity, and reproducibility. The robustness of the platform was measured against several samples of varying complexity and sample loading amount. The results indicate that capillary SP columns provide high loading capacities and that ∼6 s chromatographic peak widths are typical for standard proteins in simple mixtures and proteins isolated from cell and tissue lysates. Subfemtomole detection limits for standard proteins were consistently observed, with the lowest levels at 12 amol for ubiquitin. The analysis of total heart homogenates shows that capillary SP columns provide theoretical peak capacity of 106 protein forms with 30 min total analysis time and enabled detection of proteins from complex mixtures with a single high-resolution scan. The SPLC/MS platform also detected 343 protein forms from two HeLa acid extract replicate analyses that consumed 5 × 10(4) cells and 30 min analysis time, each. Comparison of all the species observed in each HeLa replicate showed 90% overlap (309 forms) with a Pearson correlation coefficient of 89.9% for the common forms observed in the replicates. Efficient acid extract of 1 × 10(4) HeLa cells allowed reproducible detection of common modification states and members from all five of the histone families and demonstrated that capillary SPLC/MS supports reproducible label-free profiling of histones in <15 min total analysis time. The data presented demonstrate that a capillary LC/MS platform utilizing superficially porous stationary phase and a LTQ-Orbitrap FT-MS is fast, sensitive, and reproducible for intact protein profiling from small tissue and cell amounts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac202339x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Roth, M. J., Plymire, D. A., Chang, A. N., Kim, J., Maresh, E. M., Larson, S. E., & Patrie, S. M.
Venue
Analytical Chemistry
Published
2011-11-15
Volume
83
Issue
24
Pages
9586-9592
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2314981029
Cited by
41
References
7
FWCI
2.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.