General LC-MS/MS Method Approach to Quantify Therapeutic Monoclonal Antibodies Using a Common Whole Antibody Internal Standard with Application to Preclinical Studies
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Ligand binding assays (LBAs) are widely used for therapeutic monoclonal antibody (mAb) quantification in biological samples. Major limitations are long method development times, reagent procurement, and matrix effects. LC-MS/MS methods using signature peptides are emerging as an alternative approach, which typically use a stable isotope labeled signature peptide as the internal standard (IS). However, a new IS has to be generated for every candidate, and the IS may not correct for variations at all processing steps. We have developed a general LC-MS/MS method approach employing a uniformly heavy-isotope labeled common whole mAb IS and a common immunocapture for sample processing. The method was streamlined with automation for consistency and throughput. Method qualification of four IgG(2) and four IgG(1) mAbs showed sensitivity of 0.1 μg/mL and linearity of 0.1-15 μg/mL. Quality control (QC) data of these eight mAbs were accurate and precise. The QC performance of the whole molecule labeled IS was better than those of synthetic labeled IS peptides tested. The pharmacokinetic results of two mAbs (an IgG(2) and IgG(1) candidate) dosed in rats were comparable to those of LBA. The general LC-MS/MS method approach overcomes the limitations of current methods to reduce time and resources required for preclinical studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative mass spectrometric multiple reaction monitoring assays for major plasma proteins
Anderson, L., & Hunter, C. L. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500331-mcp200 · Cited by 1,230
Monoclonal Antibody Pharmacokinetics and Pharmacodynamics
Wang, W., Wang, E., & Balthasar, J. (2008) · Clinical Pharmacology & Therapeutics · doi:10.1038/clpt.2008.170 · Cited by 978
DeSilva, B., Smith, W., Weiner, R., Kelley, M., Smolec, J., Lee, B., Khan, M., Tacey, R., Hill, H., & Celniker, A. (2003) · Pharmaceutical Research · doi:10.1023/b:pham.0000003390.51761.3d · Cited by 623
Validation of immunoassays for bioanalysis: a pharmaceutical industry perspective
Findlay, J. W. A., Smith, W. C., Lee, J. W., Nordblom, G. D., Das, I., DeSilva, B. S., Khan, M. N., & Bowsher, R. R. (2000) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(99)00244-7 · Cited by 589
Self-citationIsotope-labeled Protein Standards
Brun, V., Dupuis, A., Adrait, A., Marcellin, M., Thomas, D., Court, M., Vandenesch, F., & Garin, J. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700163-mcp200 · Cited by 445
Heudi, O., Barteau, S., Zimmer, D., Schmidt, J., Bill, K., Lehmann, N., Bauer, C., & Kretz, O. (2008) · Analytical Chemistry · doi:10.1021/ac800205s · Cited by 231
Regulation of Leucine Metabolism in Man: A Stable Isotope Study
Matthews, D. E., Bier, D. M., Rennie, M. J., Edwards, R. H. T., Halliday, D., Millward, D. J., & Clugston, G. A. (1981) · Science · doi:10.1126/science.7302583 · Cited by 189
Dubois, M., Fenaille, F., Clement, G., Lechmann, M., Tabet, J., Ezan, É., & Bécher, F. (2008) · Analytical Chemistry · doi:10.1021/ac7021234 · Cited by 154
Rivers, J., Simpson, D. M., Robertson, D. H. L., Gaskell, S. J., & Beynon, R. J. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600456-mcp200 · Cited by 152
Hagman, C., Ricke, D. O., Ewert, S., Bek, S., Falchetto, R. A., & Bitsch, F. (2008) · Analytical Chemistry · doi:10.1021/ac702115b · Cited by 126
Cited by
Characterization of Therapeutic Antibodies and Related Products
Beck, A., Wagner-Rousset, E., Ayoub, D., Van Dorsselaer, A., & Sanglier-Cianférani, S. (2013) · Analytical Chemistry · doi:10.1021/ac3032355 · Cited by 587
Bioanalytical Assay Strategies for The Development of Antibody–Drug Conjugate Biotherapeutics
Kaur, S., Xu, K., Saad, O. M., Dere, R. C., & Carrasco-Triguero, M. (2013) · Bioanalysis · doi:10.4155/bio.12.299 · Cited by 236
Bioanalytical LC–MS/MS of protein-based biopharmaceuticals
van den Broek, I., Niessen, W. M. A., & van Dongen, W. D. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.04.030 · Cited by 232
Recommendations for Validation of LC-MS/MS Bioanalytical Methods for Protein Biotherapeutics
Jenkins, R., Duggan, J. X., Aubry, A.-F., Zeng, J., Lee, J. W., Cojocaru, L., Dufield, D., Garofolo, F., Kaur, S., Schultz, G. A., et al. (2015) · The AAPS Journal · doi:10.1208/s12248-014-9685-5 · Cited by 181
“For example, the application of affinity capture in a protein LC-MS/MSmethod may significantly enhance the selectivity of the assay due to the distinctive ability of the capture reagent to bind the analyte over the matrix components.”
BackgroundSelf-citation
Metadata
- Authors
- Li, H., Ortiz, R., Tran, L., Hall, M., Spahr, C., Walker, K., Laudemann, J., Miller, S., Salimi-Moosavi, H., & Lee, J. W.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-25
- Volume
- 84
- Issue
- 3
- Pages
- 1267-1273
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2039037168
- Cited by
- 194
- References
- 17
- FWCI
- 8.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: General LC-MS/MS Method Approach to Quantify Therapeutic Monoclonal Antibodies Using a Common Whole Antibody Internal Standard with Application to Preclinical Studies. https://app.cochat.ai/papers/10.1021/ac202792n
- The paper
- Li, H., Ortiz, R., Tran, L., Hall, M., Spahr, C., Walker, K., Laudemann, J., Miller, S., Salimi-Moosavi, H., & Lee, J. W. (2012). General LC-MS/MS Method Approach to Quantify Therapeutic Monoclonal Antibodies Using a Common Whole Antibody Internal Standard with Application to Preclinical Studies. Analytical Chemistry. https://doi.org/10.1021/ac202792n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.