This paper presents a cost-effective, rapid, and fully automated lab-on-a-disc for simultaneous detection of multiple protein biomarkers in raw samples such as whole blood or whole saliva. For the diagnosis of cardiovascular disease, here, a novel centrifugal microfluidic layout was designed to conduct the simultaneous detection of high sensitivity C-reactive protein, cardiac troponin I, and N-terminal pro-B type natriuretic peptide based on a bead-based sandwich type enzyme-linked immunosorbent assay (ELISA). Three reaction chambers are initially interconnected for the common processes such as sample injection, incubation, and washing and then isolated on-demand for the independent processes such as substrate incubation and final detection. The assay performances such as the limit of detection and the dynamic range were comparable with those of the conventional ELISA despite the significant reduction of the minimum sample volume (200 μL), the amount of washing buffer (700 μL), and the total process time (20 min).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac203163u

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 164

Metadata

Authors
Park, J., Sunkara, V., Kim, T.-H., Hwang, H., & Cho, Y.-K.
Venue
Analytical Chemistry
Published
2012-02-13
Volume
84
Issue
5
Pages
2133-2140
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2324857102
Cited by
164
References
0
FWCI
9.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lab-on-a-Disc for Fully Integrated Multiplex Immunoassays. https://app.cochat.ai/papers/10.1021/ac203163u
The paper
Park, J., Sunkara, V., Kim, T.-H., Hwang, H., & Cho, Y.-K. (2012). Lab-on-a-Disc for Fully Integrated Multiplex Immunoassays. Analytical Chemistry. https://doi.org/10.1021/ac203163u

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.