The DOI matches its Crossref record; 221 of the 221 references it cites were found in a registry or an index.
High Resolution Mass Spectrometry
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVReviewNEXTHigh Resolution Mass SpectrometryFeng Xian†, Christopher L. Hendrickson*†‡, and Alan G. Marshall*†‡View Author Information† Department of Chemistry and Biochemistry, Florida State University, 95 Chieftain Way, Tallahassee, Florida 32310-4390, United States‡ Ion Cyclotron Resonance Program, National High Magnetic Field Laboratory, 1800 East Paul Dirac Drive, Tallahassee, Florida 32310-4005, United States*E-mail: [email protected] (A.G.M.); [email protected] (C.L.H.).Cite this: Anal. Chem. 2012, 84, 2, 708–719Publication Date (Web):January 17, 2012Publication History Published online17 January 2012Published inissue 17 January 2012https://pubs.acs.org/doi/10.1021/ac203191thttps://doi.org/10.1021/ac203191treview-articleACS PublicationsCopyright © 2012 American Chemical SocietyRequest reuse permissionsArticle Views11495Altmetric-Citations210LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail Other access optionsGet e-Alertsclose SUBJECTS:Electrodes,Ions,Mass spectrometry,Mathematical methods,Power Get e-Alerts
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Time-of-Flight Mass Spectrometer with Improved Resolution
Wiley, W. C., & McLaren, I. H. (1955) · Review of Scientific Instruments · doi:10.1063/1.1715212 · Cited by 3,678
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Self-citationThe Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Finding Statistically Significant Communities in Networks
Lancichinetti, A., Radicchi, F., Ramasco, J. J., & Fortunato, S. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018961 · Cited by 1,187
Fourier transform ion cyclotron resonance spectroscopy
Comisarow, M. B., & Marshall, A. G. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)89137-2 · Cited by 1,038
Self-citationAsphaltenes, Heavy Oils, and Petroleomics
(2007) · Springer eBooks · doi:10.1007/0-387-68903-6 · Cited by 1,022
Self-citationElectrostatic Axially Harmonic Orbital Trapping: A High-Performance Technique of Mass Analysis
Makarov, A. (2000) · Analytical Chemistry · doi:10.1021/ac991131p · Cited by 1,009
Research works printed but not linked: 9
- Shchepunov V., 2010, Proceedings of the 58th ASMS Conference on Mass Spectrometry & Allied Topics
- Bartholdi E., 1969, J. Magn. Reson., 1973, 9
- Shi S. D.-H., 1999, Int. J. Mass Spectrom., 195, 591
- Lange O., 2011, Proceedings of the 59th ASMS Conference on Mass Spectrometry & Allied Topics
- Pesavento J. J., 2008, J. Proteome Res., 283, 14927
- Huan H., 2010, Int. J. Mass Spectrom., 305, 116
- Huan H., 2011, Energy Fuels, 26, 4770
- Pol J., 2011, Plos ONE, 6, 1
- Giardina M., 2010, Proceedings of the 58th ASMS Conference on Mass Spectrometry & Allied Topics
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Liu, Y., D'Agostino, L. A., Qu, G., Jiang, G., & Martin, J. W. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.02.021 · Cited by 344
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Chemical modification of amino acids by atmospheric-pressure cold plasma in aqueous solution
Takai, E., Kitamura, T., Kuwabara, J., Ikawa, S., Yoshizawa, S., Shiraki, K., Kawasaki, H., Arakawa, R., & Kitano, K. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/28/285403 · Cited by 315
Metadata
- Authors
- Xian, F., Hendrickson, C. L., & Marshall, A. G.
- Affiliations
- Florida State University (US)
- Corresponding author
- Hendrickson, Christopher L.
- Marshall, Alan G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-01-17
- Volume
- 84
- Issue
- 2
- Pages
- 708-719
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2327243445
- Cited by
- 281
- References
- 220
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 14 · 2023: 17 · 2022: 22 · 2021: 37 · 2020: 18 · 2019: 19 · 2018: 22 · 2017: 19 · 2016: 18 · 2015: 22 · 2014: 25 · 2013: 17 · 2012: 9
- FWCI
- 10.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Keywords
- high-resolution mass spectrometry, ion cyclotron resonance, mass spectrometry instrumentation, ion detection, power series expansion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.