The DOI matches its Crossref record.
Detection of Adenosine Triphosphate with an Aptamer Biosensor Based on Surface-Enhanced Raman Scattering
Abstract
A simple, ultrasensitive, highly selective, and reagent-free aptamer-based biosensor has been developed for quantitative detection of adenosine triphosphate (ATP) using surface-enhanced Raman scattering (SERS). The sensor contains a SERS probe made of gold nanostar@Raman label@SiO(2) core-shell nanoparticles in which the Raman label (malachite green isothiocyanate, MGITC) molecules are sandwiched between a gold nanostar core and a thin silica shell. Such a SERS probe brings enhanced signal and low background fluorescence, shows good water-solubility and stability, and exhibits no sign of photobleaching. The aptamer labeled with the SERS probe is designed to hybridize with the cDNA on a gold film to form a rigid duplex DNA. In the presence of ATP, the interaction between ATP and the aptamer results in the dissociation of the duplex DNA structure and thereby removal of the SERS probe from the gold film, reducing the Raman signal. The response of the SERS biosensor varies linearly with the logarithmic ATP concentration up to 2.0 nM with a limit of detection of 12.4 pM. Our work has provided an effective method for detection of small molecules with SERS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface-Enhanced Raman Spectroscopy for Bioanalysis: Reliability and Challenges
Zong, C., Xu, M., Xu, L.-J., Wei, T., Ma, X., Zheng, X.-S., Hu, R., & Ren, B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00668 · Cited by 1,934
SERS Tags: Novel Optical Nanoprobes for Bioanalysis
Wang, Y., Yan, B., & Chen, L. (2013) · Chemical Reviews · doi:10.1021/cr300120g · Cited by 1,331
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Self-citationA Review on Surface-Enhanced Raman Scattering
Pilot, R., Signorini, R., Durante, C., Orian, L., Bhamidipati, M., & Fabris, L. (2019) · Biosensors · doi:10.3390/bios9020057 · Cited by 1,010
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Nanostructured Sensors for Detection of Heavy Metals: A Review
Li, M., Gou, H., Al-Ogaidi, I., & Wu, N. (2013) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc400019a · Cited by 606
Self-citationCarbon nanotubes as optical biomedical sensors
Kruss, S., Hilmer, A. J., Zhang, J., Reuel, N. F., Mu, B., & Strano, M. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.015 · Cited by 413
Self-citationLiu, Y., Zhou, H., Hu, Z., Yu, G., Yang, D., & Zhao, J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.02.032 · Cited by 388
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Self-citationSite-directed antibody immobilization techniques for immunosensors
Makaraviciute, A., & Ramanaviciene, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.060 · Cited by 316
Optical aptasensors for quantitative detection of small biomolecules: A review
Feng, C., Dai, S., & Wang, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.014 · Cited by 300
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Li, M., Cushing, S. K., Zhang, J., Suri, S., Evans, R., Petros, W. P., Gibson, L. F., Ma, D., Liu, Y., & Wu, N. (2013) · ACS Nano · doi:10.1021/nn4018284 · Cited by 275
Self-citationSelf‐Assembled Plasmonic Nanoring Cavity Arrays for SERS and LSPR Biosensing
Im, H., Bantz, K. C., Lee, S. H., Johnson, T. W., Haynes, C. L., & Oh, S. (2013) · Advanced Materials · doi:10.1002/adma.201204283 · Cited by 273
A review of aptamer-based SERS biosensors: Design strategies and applications
Muhammad, M., & Huang, Q. (2021) · Talanta · doi:10.1016/j.talanta.2021.122188 · Cited by 179
Metadata
- Authors
- Li, M., Zhang, J., Suri, S., Sooter, L. J., Ma, D., & Wu, N.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-02-29
- Volume
- 84
- Issue
- 6
- Pages
- 2837-2842
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2080739890
- Cited by
- 197
- References
- 0
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.