Mass ign: An Assignment Strategy for Maximizing Information from the Mass Spectra of Heterogeneous Protein Assemblies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Electrospray ionization mass spectrometry (ESI-MS) has evolved into a powerful adjunct for structural biology, helping to unravel the quaternary structure of protein complexes. Increasing interest has led to the study of ever larger multicomponent systems. Investigating these large complexes with ESI has meant that progressively more complicated mass spectra have been recorded. Correct assignment of these spectra is essential to maximize the information content available. Here we present a new assignment strategy and a supporting software package that allows the investigation of large heterogeneous systems, previously beyond the scope of full spectral assignment due to their complexity. The strategy involves two parts. The first includes a peak fitting routine to determine charge state distributions and consequently the masses of the various subcomplexes. The second module distinguishes between solution and gas phase products depending on their mass to charge ratio and assigns these charge states to different subunit combinations. These fitting and assignment routines contain many internal checks for consistency and reveal mass shifts, dependent upon desolvation conditions and small molecule binding. Using a rotary ATPase as a working example, we show how this assignment strategy is capable of determining the stoichiometry and interactions of the 8 different subunits within this 29-subunit assembly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Tandem Mass Spectrometer for Improved Transmission and Analysis of Large Macromolecular Assemblies
Sobott, F., Hernández, H., McCammon, M. G., Tito, M. A., & Robinson, C. V. (2002) · Analytical Chemistry · doi:10.1021/ac0110552 · Cited by 511
Self-citation
Cited by
Marty, M. T., Baldwin, A. J., Marklund, E. G., Hochberg, G. K. A., Benesch, J. L. P., & Robinson, C. V. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00140 · Cited by 1,000
Self-citationHigh-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Morgner, N., Schmidt, C., Beilsten-Edmands, V., Ebong, I.-O., Patel, N. A., Clerico, E. M., Kirschke, E., Daturpalli, S., Jackson, S. E., Agard, D., et al. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.03.063 · Cited by 106
“1 with minimal smoothing and analyzed using Massign (Morgner and Robinson, 2012) and Unidec (Marty et al., 2015) software.”
MethodSelf-citationMass spectrometry: From plasma proteins to mitochondrial membranes
Robinson, C. V. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1820450116 · Cited by 53
“Designing new software to assign these spectra (25), applying quantitative proteomics and lipidomics, and confirming these interactions by tandem MS, we revealed lipids bound directly to c-subunits within the rotor (Fig.”
BackgroundSelf-citationEpsin and Sla2 form assemblies through phospholipid interfaces
Garcia-Alai, M. M., Heidemann, J., Skruzny, M., Gieras, A., Mertens, H. D. T., Svergun, D. I., Kaksonen, M., Uetrecht, C., & Meijers, R. (2018) · Nature Communications · doi:10.1038/s41467-017-02443-x · Cited by 52
Metadata
- Authors
- Morgner, N., & Robinson, C. V.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-07
- Volume
- 84
- Issue
- 6
- Pages
- 2939-2948
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318823565
- Cited by
- 151
- References
- 1
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.