Improved Protein Hydrogen/Deuterium Exchange Mass Spectrometry Platform with Fully Automated Data Processing
The DOI matches its Crossref record.
Abstract
Protein hydrogen/deuterium exchange (HDX) followed by protease digestion and mass spectrometric (MS) analysis is accepted as a standard method for studying protein conformation and conformational dynamics. In this article, an improved HDX MS platform with fully automated data processing is described. The platform significantly reduces systematic and random errors in the measurement by introducing two types of corrections in HDX data analysis. First, a mixture of short peptides with fast HDX rates is introduced as internal standards to adjust the variations in the extent of back exchange from run to run. Second, a designed unique peptide (PPPI) with slow intrinsic HDX rate is employed as another internal standard to reflect the possible differences in protein intrinsic HDX rates when protein conformations at different solution conditions are compared. HDX data processing is achieved with a comprehensive HDX model to simulate the deuterium labeling and back exchange process. The HDX model is implemented into the in-house developed software MassAnalyzer and enables fully unattended analysis of the entire protein HDX MS data set starting from ion detection and peptide identification to final processed HDX output, typically within 1 day. The final output of the automated data processing is a set (or the average) of the most possible protection factors for each backbone amide hydrogen. The utility of the HDX MS platform is demonstrated by exploring the conformational transition of a monoclonal antibody by increasing concentrations of guanidine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Walls, A. C., Fiala, B., Schäfer, A., Wrenn, S., Pham, M. N., Murphy, M., Tse, L. V., Shehata, L., O’Connor, M. A., Chen, C., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.043 · Cited by 532
James, E. I., Murphree, T. A., Vorauer, C., Engen, J. R., & Guttman, M. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00279 · Cited by 305
Native ion mobility-mass spectrometry and related methods in structural biology
Konijnenberg, A., Butterer, A., & Sobott, F. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2012.11.013 · Cited by 245
“They introduce two internal peptide standards with high and low exchange rates to reduce systematic and random errors [117].”
BackgroundLiu, X. R., Zhang, M. M., & Gross, M. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00815 · Cited by 242
Minimizing Back Exchange in the Hydrogen Exchange-Mass Spectrometry Experiment
Walters, B. T., Ricciuti, A., Mayne, L., & Englander, S. W. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0476-x · Cited by 182
“Because back exchange quickly degrades HX MS analysis, it continues to receive a great deal of attention [8, 12, 21–29].”
Toward Biotherapeutic Product Real‐Time Quality Monitoring
Guerra, A., von Stosch, M., & Glassey, J. (2019) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2018.1524362 · Cited by 58
Impact of Fc N-glycan sialylation on IgG structure
Zhang, Z., Shah, B., & Richardson, J. (2019) · mAbs · doi:10.1080/19420862.2019.1655377 · Cited by 46
Self-citation
Metadata
- Authors
- Zhang, Z., Zhang, A., & Xiao, G.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-06-05
- Volume
- 84
- Issue
- 11
- Pages
- 4942-4949
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2318406615
- Cited by
- 118
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.