Detection of Inflammation in Vivo by Surface-Enhanced Raman Scattering Provides Higher Sensitivity Than Conventional Fluorescence Imaging
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The detection of inflammatory changes is a key aim for the early diagnosis and treatment of several autoimmune, infectious, and metastatic diseases. While surface-enhanced Raman scattering (SERS) has the capability to provide noninvasive, in vivo imaging at sufficient depth to achieve this goal, this approach has not been exploited in the study of inflammation. SERS-active nanoparticles were coded with a unique Raman signal that was protected under a wide range of conditions and stimuli. To detect early-stage inflammation, gold nanoparticle clusters containing Raman-active molecules were conjugated to intercellular adhesion molecule 1- (ICAM-1-) specific monoclonal antibodies. SERS allowed noninvasive measurement of ICAM-1 expression in vivo with twice the sensitivity of two-photon fluorescence. This is the first time SERS has been used for in vivo detection of inflammation and is a major advance in the ever-growing toolkit of approaches for use in noninvasive, next-generation in vivo imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Bhattacharya, K., Davoren, M., Boertz, J., Schins, R. P., Hoffmann, E., & Dopp, E. (2009) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-6-17 · Cited by 348
Stone, N., Faulds, K., Graham, D., & Matousek, P. (2010) · Analytical Chemistry · doi:10.1021/ac100039c · Cited by 140
Self-citation
Cited by
SERS Tags: Novel Optical Nanoprobes for Bioanalysis
Wang, Y., Yan, B., & Chen, L. (2013) · Chemical Reviews · doi:10.1021/cr300120g · Cited by 1,331
Surface-enhanced Raman spectroscopy for in vivo biosensing
Laing, S., Jamieson, L. E., Faulds, K., & Graham, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0060 · Cited by 442
Self-citationHarmsen, S., Bedics, M. A., Wall, M. A., Huang, R., Detty, M. R., & Kircher, M. F. (2015) · Nature Communications · doi:10.1038/ncomms7570 · Cited by 137
Noonan, J., Asiala, S. M., Grassia, G., MacRitchie, N., Gracie, K., Carson, J., Moores, M., Girolami, M., Bradshaw, A. C., Guzik, T. J., et al. (2018) · Theranostics · doi:10.7150/thno.28665 · Cited by 69
“Molecule-specific BFNP were developed—a strategy employed in several other studies [16,17,19-22,35]—as a means of detecting adhesion molecules using SERS.”
BackgroundMethodSelf-citationZhang, Y., Chen, R., Liu, F., Miao, P., Lin, L., & Ye, J. (2023) · Small Methods · doi:10.1002/smtd.202201334 · Cited by 52
Metadata
- Authors
- McQueenie, R., Stevenson, R., Benson, R., MacRitchie, N., McInnes, I., Maffia, P., Faulds, K., Graham, D., Brewer, J., & Garside, P.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-03
- Volume
- 84
- Issue
- 14
- Pages
- 5968-5975
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2081426224
- Cited by
- 66
- References
- 4
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.