Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Optical Aptasensors for the Analysis of the Vascular Endothelial Growth Factor (VEGF)

Open access
Freeman, Ronit, Girsh, Julia, Fang-ju Jou, Amily, Ho, Ja-an Annie, Hug, Thomas, Dernedde, Jens, Willner, Itamar·2012·Analytical Chemistry

Abstract

The vascular endothelial growth factor, VEGF, is an important biomarker for different diseases and clinical disorders. We present a series of optical aptasensor-based sensing platforms for VEGF that include the following: (i) A FRET-based sensor that involves the VEGF-induced separation of aptamer-functionalized quantum dots blocked by a quencher nucleic acid (detection limit 1 nM). (ii) A FRET-based sensor based on the VEGF-induced assembly of the aptamer subunits functionalized with QDs and a dye acceptor (Cy5), respectively (detection limit 12 nM). (iii) A chemiluminescence aptasensor based on VEGF-induced assembly of a hemin/G-quadruplex catalyst (detection limit 18 nM). (iv) A chemiluminescence aptasensor based on the VEGF-stimulated assembly of two aptamer subunits into the hemin/G-quadruplex catalyst (detection limit 2.6 nM). (v) A chemiluminescence resonance energy transfer (CRET) aptasensor based on the VEGF-induced assembly of a semiconductor QDs-hemin/G-quadruplex supramolecular structure (detection limit 875 pM). Furthermore, an amplified optical aptasensor system based on the Exonuclease III (Exo III) recycling of the VEGF analyte was developed. In this system, one aptamer subunit is modified at its 5' and 3' ends with QDs and a black hole quencher, respectively. The VEGF-induced self-assembly of the aptamer subunits result in the digestion of the quencher units and the autonomous recycling of the analyte, while triggering-on the luminescence of the QDs (detection limit 5 pM). The system was implemented to analyze VEGF in human sera samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac3011473

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 186

Metadata

Authors
Freeman, R., Girsh, J., Fang-ju Jou, A., Ho, J.-A. A., Hug, T., Dernedde, J., & Willner, I.
Venue
Analytical Chemistry
Published
2012-07-05
Volume
84
Issue
14
Pages
6192-6198
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W1976388431
Cited by
186
References
2
FWCI
9.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.