CoChat

Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid–Liquid Microextraction Using Lumogallion

Suárez, Ruth, Horstkotte, Burkhard, Duarte, Carlos M., Cerdà, Víctor · 2012 · Analytical Chemistry
Cited by 52

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

A sensitive and selective automated in-syringe dispersive liquid-liquid microextraction (DLLME) method is presented. It was successfully applied to the determination of aluminum in coastal seawater samples. The complete analytical procedure including sampling, buffering, reaction of the analyte with fluorescence reagent lumogallion (LMG), extraction, phase separation, and quantification was completely automized and carried out within 4 min. DLLME was done using n-hexanol as an extracting solvent and ethanol as a dispersing solvent in a 1:8 v/v percent mixture. The Al-LMG complex was extracted by an organic solvent and separated from the aqueous phase within the syringe of an automated syringe pump. Two devices were specially developed for this work. These were (a) the fluorescence detector and accompanying flow cell for the organic phase enriched with the reaction product and (b) a heating device integrated into the holding coil to accelerate the slow reaction kinetics. The limits of detection (3σ) and quantification (10σ) were 8.0 ± 0.5 nmol L(-1) and 26.7 ± 1.6 nmol L(-1), respectively. The relative standard deviation for eight replicate determinations of 200 nmol L(-1) Al(3+) was <1.5%. The calibration graph using the preconcentration system was linear up to 1000 nmol L(-1) with a correlation coefficient of 0.999. Ambient concentrations of samples were quantifiable with found concentrations ranging from 43 to 142 nmol L(-1). Standard additions gave analyte recoveries from 97% to 113% proving the general applicability and adequateness of the analyzer system to real sample analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac302083d

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 52

Metadata

Authors
Suárez, R., Horstkotte, B., Duarte, C. M., & Cerdà, V.
Venue
Analytical Chemistry
Published
2012-10-10
Volume
84
Issue
21
Pages
9462-9469
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2093195155
Cited by
52
References
5
FWCI
7.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid–Liquid Microextraction Using Lumogallion. https://app.cochat.ai/papers/10.1021/ac302083d
The paper
Suárez, R., Horstkotte, B., Duarte, C. M., & Cerdà, V. (2012). Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid–Liquid Microextraction Using Lumogallion. Analytical Chemistry. https://doi.org/10.1021/ac302083d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.