Toward Full Peptide Sequence Coverage by Dual Fragmentation Combining Electron-Transfer and Higher-Energy Collision Dissociation Tandem Mass Spectrometry
Open accessAbstract
Increasing peptide sequence coverage by tandem mass spectrometry improves confidence in database search-based peptide identification and facilitates mapping of post-translational modifications and de novo sequencing. Inducing 2-fold fragmentation by combining electron-transfer and higher-energy collision dissociation (EThcD) generates dual fragment ion series and facilitates extensive peptide backbone fragmentation. After an initial electron-transfer dissociation step, all ions including the unreacted precursor ions are subjected to collision induced dissociation which yields b/y- and c/z-type fragment ions in a single spectrum. This new fragmentation scheme provides richer spectra and substantially increases the peptide sequence coverage and confidence in peptide identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Semi-supervised learning for peptide identification from shotgun proteomics datasets
Käll, L., Canterbury, J. D., Weston, J., Noble, W. S., & MacCoss, M. J. (2007) · Nature Methods · doi:10.1038/nmeth1113 · Cited by 2,424
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Protein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180
The utility of ETD mass spectrometry in proteomic analysis
Mikesh, L. M., Ueberheide, B., Chi, A., Coon, J. J., Syka, J. E. P., Shabanowitz, J., & Hunt, D. F. (2006) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2006.10.003 · Cited by 535
Performance Characteristics of Electron Transfer Dissociation Mass Spectrometry
Good, D. M., Wirtala, M., McAlister, G. C., & Coon, J. J. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700073-mcp200 · Cited by 396
Swaney, D. L., McAlister, G. C., Wirtala, M., Schwartz, J. C., Syka, J. E. P., & Coon, J. J. (2007) · Analytical Chemistry · doi:10.1021/ac061457f · Cited by 363
Activated Ion Electron Capture Dissociation for Mass Spectral Sequencing of Larger (42 kDa) Proteins
Horn, D. M., Ge, Y., & McLafferty, F. W. (2000) · Analytical Chemistry · doi:10.1021/ac000494i · Cited by 333
A computer program for predicting protein antigenic determinants
Hopp, T. P., & Woods, K. R. (1983) · Molecular Immunology · doi:10.1016/0161-5890(83)90029-9 · Cited by 317
Frese, C. K., Altelaar, A. F. M., Hennrich, M. L., Nolting, D., Zeller, M., Griep-Raming, J., Heck, A. J. R., & Mohammed, S. (2011) · Journal of Proteome Research · doi:10.1021/pr1011729 · Cited by 312
Self-citationAutomated de novo sequencing of proteins by tandem high-resolution mass spectrometry
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.19.10313 · Cited by 243
Nonergodic and conformational control of the electron capture dissociation of protein cations
Breuker, K., Oh, H., Lin, C., Carpenter, B. K., & McLafferty, F. W. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406095101 · Cited by 170
Electron capture/transfer versus collisionally activated/induced dissociations: Solo or duet?
Zubarev, R. A., Zubarev, A. R., & Savitski, M. M. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.03.007 · Cited by 152
Straightforward ladder sequencing of peptides using a Lys-N metalloendopeptidase
Taouatas, N., Drugan, M. M., Heck, A. J. R., & Mohammed, S. (2008) · Nature Methods · doi:10.1038/nmeth.1204 · Cited by 141
Self-citationNielsen, M. L., Savitski, M. M., & Zubarev, R. A. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400022-mcp200 · Cited by 140
The quantitative proteomes of human‐induced pluripotent stem cells and embryonic stem cells
Muñoz, J., Low, T. Y., Kok, Y. J., Chin, A. C. P., Frese, C. K., Ding, V., Choo, A. B. H., & Heck, A. J. R. (2011) · Molecular Systems Biology · doi:10.1038/msb.2011.84 · Cited by 133
Self-citationPitteri, S. J., Chrisman, P. A., & McLuckey, S. A. (2005) · Analytical Chemistry · doi:10.1021/ac050666h · Cited by 124
Comprehensive Comparison of Collision Induced Dissociation and Electron Transfer Dissociation
Molina, H., Matthiesen, R., Kandasamy, K., & Pandey, A. (2008) · Analytical Chemistry · doi:10.1021/ac8007785 · Cited by 110
Ledvina, A. R., McAlister, G. C., Gardner, M. W., Smith, S. I., Madsen, J. A., Schwartz, J. C., Stafford, G. C., Syka, J. E. P., Brodbelt, J. S., & Coon, J. J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200903557 · Cited by 103
de Graaf, E. L., Altelaar, M. A. F., van Breukelen, B., Mohammed, S., & Heck, A. J. R. (2011) · Journal of Proteome Research · doi:10.1021/pr200156b · Cited by 95
Self-citationCampbell, J. L., Hager, J. W., & Blanc, J. C. Y. L. (2009) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2009.05.009 · Cited by 28
Liu, C., & Lai, C. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-010-0020-9 · Cited by 11
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Self-citationMass spectrometry approaches to glycomic and glycoproteomic analyses
Ruhaak, L. R., Xu, G., Li, Q., Goonatilleke, E., & Lebrilla, C. B. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00732 · Cited by 395
Recent advances in mass spectrometry based clinical proteomics: applications to cancer research
Macklin, A., Khan, S., & Kislinger, T. (2020) · Clinical Proteomics · doi:10.1186/s12014-020-09283-w · Cited by 317
Terminology of bioanalytical methods (IUPAC Recommendations 2018)
Labuda, J., Bowater, R. P., Fojta, M., Gauglitz, G., Glatz, Z., Hapala, I., Havliš, J., Kilar, F., Kilar, A., Malinovská, L., et al. (2018) · Pure and Applied Chemistry · doi:10.1515/pac-2016-1120 · Cited by 287
ProSight Lite: Graphical software to analyze top‐down mass spectrometry data
Fellers, R. T., Greer, J. B., Early, B. P., Yu, X., LeDuc, R. D., Kelleher, N. L., & Thomas, P. M. (2015) · PROTEOMICS · doi:10.1002/pmic.201400313 · Cited by 247
Metadata
- Authors
- Frese, C. K., Altelaar, A. F. M., van den Toorn, H., Nolting, D., Griep-Raming, J., Heck, A. J. R., & Mohammed, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-31
- Volume
- 84
- Issue
- 22
- Pages
- 9668-9673
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2029325590
- Cited by
- 304
- References
- 25
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.