The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Label-Free and Ultrasensitive Electrochemical Detection of Nucleic Acids Based on Autocatalytic and Exonuclease III-Assisted Target Recycling Strategy
Abstract
In this work, a very simple, label-free, isothermal, and ultrasensitive electrochemical DNA biosensor has been developed on the basis of an autocatalytic and exonuclease III (Exo III)-assisted target recycling amplification strategy. A duplex DNA probe constructed by the hybridization of a quadruplex-forming oligomer with a molecular beacon is ingeniously designed and assembled on the electrode as recognition element. Upon sensing of the analyte nucleic acid, the strand of molecular beacon in the duplex DNA probe could be stepwise removed by Exo III accompanied by the releasing of target DNA and autonomous generation of new secondary target DNA fragment for the successive hybridization and cleavage process. Simultaneously, numerous quadruplex-forming oligomers are liberated and folded into G-quadruplex-hemin complexes with the help of K(+) and hemin on the electrode surface to give a remarkable electrochemical response. Because of this autocatalytic target recycling amplification and the specifically catalyzed formation of G-quadruplex-hemin complexes, this newly designed protocol provides an ultrasensitive electrochemical detection of DNA down to the 10 fM level, can discriminate mismatched DNA from perfectly matched target DNA, and holds a great potential for early diagnosis in gene-related diseases. It further could be developed as a universal protocol for the detection of various DNA sequences and may be extended for the detection of aptamer-binding molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J., Song, S., Zhang, L., Wang, L., Wu, H., Pan, D., & Fan, C. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061521a · Cited by 424
Cited by
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Wang, F., Lu, C.-H., & Willner, I. (2014) · Chemical Reviews · doi:10.1021/cr400354z · Cited by 649
Isothermal amplified detection of DNA and RNA
Yan, L., Zhou, J., Zheng, Y., Gamson, A. S., Roembke, B. T., Nakayama, S., & Sintim, H. O. (2014) · Molecular BioSystems · doi:10.1039/c3mb70304e · Cited by 446
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Nucleic Acid Tests for Clinical Translation
Li, M., Yin, F., Song, L., Mao, X., Li, F., Fan, C., Zuo, X., & Xia, Q. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00241 · Cited by 264
Metadata
- Authors
- Liu, S., Wang, C., Zhang, C., Wang, Y., & Tang, B.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-01-28
- Volume
- 85
- Issue
- 4
- Pages
- 2282-2288
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2325669821
- Cited by
- 164
- References
- 1
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-Free and Ultrasensitive Electrochemical Detection of Nucleic Acids Based on Autocatalytic and Exonuclease III-Assisted Target Recycling Strategy. https://app.cochat.ai/papers/10.1021/ac303225p
- The paper
- Liu, S., Wang, C., Zhang, C., Wang, Y., & Tang, B. (2013). Label-Free and Ultrasensitive Electrochemical Detection of Nucleic Acids Based on Autocatalytic and Exonuclease III-Assisted Target Recycling Strategy. Analytical Chemistry. https://doi.org/10.1021/ac303225p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.