Label-Free DNA Biosensor Based on SERS Molecular Sentinel on Nanowave Chip
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Development of a rapid, cost-effective, label-free biosensor for DNA detection is important for many applications in clinical diagnosis, homeland defense, and environment monitoring. A unique label-free DNA biosensor based on Molecular Sentinel (MS) immobilized on a plasmonic 'Nanowave' chip, which is also referred to as a metal film over nanosphere (MFON), is presented. Its sensing mechanism is based upon the decrease of the surface-enhanced Raman scattering (SERS) intensity when Raman label tagged at one end of MS is physically separated from the MFON's surface upon DNA hybridization. This method is label-free as the target does not have to be labeled. The MFON fabrication is relatively simple and low-cost with high reproducibility based on depositing a thin shell of gold over close-packed arrays of nanospheres. The sensing process involves a single hybridization step between the DNA target sequences and the complementary MS probes on the Nanowave chip without requiring secondary hybridization or posthybridization washing, thus resulting in rapid assay time and low reagent usage. The usefulness and potential application of the biosensor for medical diagnostics is demonstrated by detecting the human radical S-adenosyl methionine domain containing 2 (RSAD2) gene, a common inflammation biomarker.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vo-Dinh, T. (1998) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00069-7 · Cited by 498
Self-citationThe Interferon Inducible Gene: Viperin
Fitzgerald, K. A. (2011) · Journal of Interferon & Cytokine Research · doi:10.1089/jir.2010.0127 · Cited by 163
Cited by
Present and Future of Surface-Enhanced Raman Scattering
Langer, J., Jimenez de Aberasturi, D., Aizpurua, J., Alvarez-Puebla, R. A., Auguié, B., Baumberg, J. J., Bazan, G. C., Bell, S. E. J., Boisen, A., Brolo, A. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b04224 · Cited by 3,880
Self-citationA Review on Surface-Enhanced Raman Scattering
Pilot, R., Signorini, R., Durante, C., Orian, L., Bhamidipati, M., & Fabris, L. (2019) · Biosensors · doi:10.3390/bios9020057 · Cited by 1,010
Label-Free Surface-Enhanced Raman Spectroscopy Detection of DNA with Single-Base Sensitivity
Xu, L.-J., Lei, Z.-C., Li, J., Zong, C., Yang, C. J., & Ren, B. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b01426 · Cited by 456
Multiplex in vitro detection using SERS
Laing, S., Gracie, K., & Faulds, K. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00644a · Cited by 361
Carbon-based SERS biosensor: from substrate design to sensing and bioapplication
Liang, X., Li, N., Zhang, R., Yin, P., Zhang, C., Yang, N., Liang, K., & Kong, B. (2021) · NPG Asia Materials · doi:10.1038/s41427-020-00278-5 · Cited by 305
Metadata
- Authors
- Ngo, H. T., Wang, H.-N., Fales, A. M., & Vo-Dinh, T.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-12
- Volume
- 85
- Issue
- 13
- Pages
- 6378-6383
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2004913474
- Cited by
- 150
- References
- 2
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Label-Free DNA Biosensor Based on SERS Molecular Sentinel on Nanowave Chip. https://app.cochat.ai/papers/10.1021/ac400763c
- The paper
- Ngo, H. T., Wang, H.-N., Fales, A. M., & Vo-Dinh, T. (2013). Label-Free DNA Biosensor Based on SERS Molecular Sentinel on Nanowave Chip. Analytical Chemistry. https://doi.org/10.1021/ac400763c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.