The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules
Abstract
A novel reverse colorimetric immunoassay (RCIA) strategy was for the first time designed and utilized for sensitive detection of low-abundance protein (prostate-specific antigen, PSA, used in this case) in biological fluids by coupling highly catalytic efficient catalase with magnetic bead-based peroxidase mimics. To construct such a RCIA system, two nanostructures including magnetic beads and gold nanoparticles were first synthesized and functionalized with anti-PSA capture antibody and catalase/anti-PSA detection antibody, respectively. Thereafter, a specific sandwich-type immunoassay format was employed for determination of PSA by using functional gold nanoparticles as enzymatic bioreactors and anti-PSA-conjugated magnetic beads as a colorimetric developer. The carried catalase, followed by the sandwiched immunocomplex, partially consumed the added hydrogen peroxide in the detection solution, which slowed down the catalytic efficiency of magnetic bead-based peroxidase mimics toward TMB/H2O2, thereby weakening the visible color and decreasing the colorimetric density. Different from conventional colorimetric immunoassay, the RCIA method determined the residual hydrogen peroxide in the substrate after consumption. Under the optimal conditions, the developed RCIA exhibited a wide dynamic range of 0.05-20 ng mL(-1) toward PSA with a detection limit of 0.03 ng mL(-1) at the 3Sblank level. Intra- and interassay coefficients of variation were below 6.1% and 9.3%, respectively. Additionally, the methodology was further validated for the analysis of 12 PSA clinical serum specimens, giving results in good accordance with those obtained by the commercially available enzyme-linked immunosorbent assay (ELISA) method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intrinsic peroxidase-like activity of ferromagnetic nanoparticles
Gao, L., Zhuang, J., Nie, L., Zhang, J., Zhang, Y., Gu, N., Wang, T., Feng, J., Yang, D., Perrett, S., et al. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.260 · Cited by 7,483
Cited by
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes (II)
Wu, J., Wang, X., Wang, Q., Lou, Z., Li, S., Zhu, Y., Qin, L., & Wei, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00457a · Cited by 4,108
Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes
Wei, H., & Wang, E. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35486e · Cited by 3,779
Nanoparticle Probes for the Detection of Cancer Biomarkers, Cells, and Tissues by Fluorescence
Chinen, A. B., Guan, C. M., Ferrer, J. R., Barnaby, S. N., Merkel, T. J., & Mirkin, C. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00321 · Cited by 1,032
Nanozymes in bionanotechnology: from sensing to therapeutics and beyond
Wang, X., Hu, Y., & Wei, H. (2016) · Inorganic Chemistry Frontiers · doi:10.1039/c5qi00240k · Cited by 609
Lv, S., Tang, Y., Zhang, K., & Tang, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04981 · Cited by 311
Self-citation
Metadata
- Authors
- Gao, Z., Xu, M., Hou, L., Chen, G., & Tang, D.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-06-27
- Volume
- 85
- Issue
- 14
- Pages
- 6945-6952
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2334185863
- Cited by
- 220
- References
- 1
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules. https://app.cochat.ai/papers/10.1021/ac401433p
- The paper
- Gao, Z., Xu, M., Hou, L., Chen, G., & Tang, D. (2013). Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules. Analytical Chemistry. https://doi.org/10.1021/ac401433p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.