The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Oxidative Cleavage-Based Near-Infrared Fluorescent Probe for Hypochlorous Acid Detection and Myeloperoxidase Activity Evaluation
Abstract
A near-infrared (NIR) fluorescent probe was synthesized and demonstrated to be highly selective in reaction with hypochlorous acid (HOCl), an endogenous reactive oxygen species (ROS) produced by myeloperoxidase in neutrophils. The reaction with HOCl resulted in the NIR fluorescence quenching at 774 nm and the absorbance decreasing at 710 nm, accompanied by the appearance of a new absorption band at 520 nm. The reaction mechanism was carefully examined and proposed to proceed by initial formation of chlorohydrins and subsequent degradation. This NIR fluorescent probe was successfully applied as a selective and sensitive indicator for HOCl on the basis of either colorimetry or fluorometry, which showed detection limits of 0.13 and 0.70 μM, respectively. In addition, the molecular probe was further demonstrated for NIR fluorescence imaging of HOCl in cells and for evaluating the enzymatic activity of myeloperoxidase in the HOCl generation by measuring absorbance change.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Pecking Order of Free Radicals and Antioxidants: Lipid Peroxidation, α-Tocopherol, and Ascorbate
Buettner, G. R. (1993) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1993.1074 · Cited by 2,417
Antimicrobial reactive oxygen and nitrogen species: concepts and controversies
Fang, F. C. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro1004 · Cited by 1,676
Cited by
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Duan, C., Won, M., Verwilst, P., Xu, J., Kim, H. S., Zeng, L., & Kim, J. S. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00224 · Cited by 322
Zhang, R., Zhao, J., Han, G., Liu, Z., Liu, C., Zhang, C., Liu, B., Jiang, C., Liu, R., Zhao, T., et al. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b12848 · Cited by 288
Recent progress in the development of fluorescent probes for the detection of hypochlorous acid
Zhang, Y.-R., Liu, Y., Feng, X., & Zhao, B.-X. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.08.066 · Cited by 264
A general approach to the design of high-performance near-infrared (NIR) D-π-A type fluorescent dyes
Luo, X., Li, J., Zhao, J., Gu, L., Qian, X., & Yang, Y. (2019) · Chinese Chemical Letters · doi:10.1016/j.cclet.2019.03.012 · Cited by 119
Metadata
- Authors
- Sun, M., Yu, H., Zhu, H., Ma, F., Zhang, S., Huang, D., & Wang, S.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-12-12
- Volume
- 86
- Issue
- 1
- Pages
- 671-677
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2057332733
- Cited by
- 230
- References
- 2
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxidative Cleavage-Based Near-Infrared Fluorescent Probe for Hypochlorous Acid Detection and Myeloperoxidase Activity Evaluation. https://app.cochat.ai/papers/10.1021/ac403603r
- The paper
- Sun, M., Yu, H., Zhu, H., Ma, F., Zhang, S., Huang, D., & Wang, S. (2014). Oxidative Cleavage-Based Near-Infrared Fluorescent Probe for Hypochlorous Acid Detection and Myeloperoxidase Activity Evaluation. Analytical Chemistry. https://doi.org/10.1021/ac403603r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.