The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Inductively coupled argon plasma as an ion source for mass spectrometric determination of trace elements
Abstract
Solution aerosols are injected into an inductlvety coupled argon plasma (ICP) to generate a relatively high number density of positive ions derived from elemental constituents. A small fraction of these ions is extracted through a sampling orifice into a differentially pumped vacuum system housing an ion lens and quadrupole mass spectrometer. The positive ion mass spectrum obtained during nebullration of a typical solvent (1 % HNO, in H20) consists mainly of ArH', Ar', H30+, H20+, NO', 02', HO+, Ar2', Ar2H+, and Ar2+. The mass spectra of the trace elements studied consist principally of singly charged monatomic (M') or oxide (MO') ions in the correct relatlve isotopic abundances. Analytical calibration curves obtained in an integration mode show a working range covering nearly 4 orders of magnitude with detection limits of 0.002-0.06 pg/mL for those elements studied. This approach offers a direct means of performing trace elemental and isotopic determinations on solutions by mass spectrometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quadrupole Mass Spectrometry and its Applications
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-04436-2 · Cited by 700
Horning, E. C., Horning, M. G., Carroll, D. I., Dzidic, I., & Stillwell, R. N. (1973) · Analytical Chemistry · doi:10.1021/ac60328a035 · Cited by 552
Fassel, V. A. (1978) · Science · doi:10.1126/science.202.4364.183 · Cited by 294
Self-citation
Cited by
Inductively Coupled Plasma–Mass Spectrometry
(2019) · Practical Inductively Coupled Plasma Spectrometry · doi:10.1002/9781119478775.ch7 · Cited by 956
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
Inductively Coupled Plasma Mass Spectrometry: Introduction to Analytical Aspects
Wilschefski, S., & Baxter, M. (2019) · Clinical Biochemist Reviews · doi:10.33176/aacb-19-00024 · Cited by 684
Mass spectrometry of inductively coupled plasmas
Houk, R. S. (1986) · Analytical Chemistry · doi:10.1021/ac00292a003 · Cited by 464
Self-citationInterferences in inductively coupled plasma mass spectrometry. A review
Evans, E. H., & Giglio, J. J. (1993) · Journal of Analytical Atomic Spectrometry · doi:10.1039/ja9930800001 · Cited by 393
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324
Mohamed, Y., Mohamed, I., Elsadek, M., Ali, M., & Ghatas, Y. (2021) · Industrial Crops and Products · doi:10.1016/j.indcrop.2021.113637 · Cited by 10
Metadata
- Authors
- Houk, R. S., Fassel, V. A., Flesch, G. D., Svec, H. J., Gray, A. L., & Taylor, C. E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1980-12-01
- Volume
- 52
- Issue
- 14
- Pages
- 2283-2289
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2051724344
- Cited by
- 766
- References
- 3
- FWCI
- 15.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.