CoChat

Characterization and Stability Study of Polysorbate 20 in Therapeutic Monoclonal Antibody Formulation by Multidimensional Ultrahigh-Performance Liquid Chromatography–Charged Aerosol Detection–Mass Spectrometry

Li, Yi, Hewitt, Daniel, Lentz, Yvonne K., Ji, Junyan A., Zhang, Taylor Y., Zhang, Kelly · 2014 · Analytical Chemistry
Cited by 127

The DOI matches its Crossref record.

Abstract

Polysorbate 20 is a nonionic surfactant commonly used in the formulation of therapeutic monoclonal antibodies (mAb) to prevent protein denaturation and aggregation. It is critical to understand the molecular heterogeneity and stability of polysorbate 20 in mAb formulations as polysorbate can gradually degrade in aqueous solution over time by multiple pathways losing surfactant functions and leading to protein aggregation. The molecular heterogeneity of polysorbate and the interference from proteins and the excipient in the formulation matrix make it a challenge to study polysorbate in protein formulations. In this work, the characterization and stability study of polysorbate 20 in the presence of mAb formulation sample matrix is first reported using two-dimensional liquid chromatography (2DLC) coupled with charged aerosol detection (CAD) and mass spectrometry (MS) detection. A mixed-mode column that has both anion-exchange and reversed-phase properties was used in the first dimension to separate protein and polysorbate in the formulation sample, while polysorbate 20 esters were trapped online and then analyzed using an reversed-phase ultrahigh-performance liquid chromatography (RP-UHPLC) column in the second dimension to further separate the ester species. The MS served as the third dimension to further resolve as well as to identify the polysorbate ester subspecies. Another 2DLC method using a cation-exchange column in the first dimension and the same RP-UHPLC method in the second dimension was developed to analyze the degradation products of polysorbate 20. Stability samples of a protein drug product were studied using these two 2DLC-CAD-MS methods to separate, identify, and quantify the multiple ester species in polysorbate 20 and also to monitor the change of their corresponding degradants. We found different polysorbate esters degrade at different rates, and importantly, the degradation rates for some esters are different in the protein formulation compared to a placebo that has no protein. The multidimensional UHPLC-CAD-MS approach provides insights into the heterogeneous stability behaviors of polysorbate 20 subspecies in real-time stability samples of a mAb formulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ac5009628

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 127

Metadata

Authors
Li, Y., Hewitt, D., Lentz, Y. K., Ji, J. A., Zhang, T. Y., & Zhang, K.
Venue
Analytical Chemistry
Published
2014-05-02
Volume
86
Issue
10
Pages
5150-5157
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2056762093
Cited by
127
References
0
FWCI
3.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization and Stability Study of Polysorbate 20 in Therapeutic Monoclonal Antibody Formulation by Multidimensional Ultrahigh-Performance Liquid Chromatography–Charged Aerosol Detection–Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ac5009628
The paper
Li, Y., Hewitt, D., Lentz, Y. K., Ji, J. A., Zhang, T. Y., & Zhang, K. (2014). Characterization and Stability Study of Polysorbate 20 in Therapeutic Monoclonal Antibody Formulation by Multidimensional Ultrahigh-Performance Liquid Chromatography–Charged Aerosol Detection–Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/ac5009628

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.